Show simple item record

dc.contributor.authorAde, P. A. R.es_ES
dc.contributor.authorBarreiro Vilas, Rita Belén es_ES
dc.contributor.authorCurto Martín, Andréses_ES
dc.contributor.authorDiego Rodríguez, José Maríaes_ES
dc.contributor.authorGonzález-Nuevo González, Joaquínes_ES
dc.contributor.authorHerranz Muñoz, Diego es_ES
dc.contributor.authorLópez-Caniego Alcarria, Marcoses_ES
dc.contributor.authorMartínez González, Enriquees_ES
dc.contributor.authorToffolatti, Luigies_ES
dc.contributor.authorVielva Martínez, Patricio es_ES
dc.contributor.otherUniversidad de Cantabriaes_ES
dc.date.accessioned2018-06-15T11:26:07Z
dc.date.available2018-06-15T11:26:07Z
dc.date.issued2014-11es_ES
dc.identifier.issn0004-6361es_ES
dc.identifier.issn1432-0746es_ES
dc.identifier.urihttp://hdl.handle.net/10902/13913
dc.description.abstractWe describe the detection, interpretation, and removal of the signal resulting from interactions of high energy particles with the Planck High Frequency Instrument (HFI). There are two types of interactions: heating of the 0.1 K bolometer plate; and glitches in each detector time stream. The transientresponses to detector glitch shapes are not simple single-pole exponential decays and fall into three families. The glitch shape for each family has been characterized empirically in flight data and these shapes have been used to remove glitches from the detector time streams. The spectrum of the count rate per unit energy is computed for each family and a correspondence is made to the location on the detector of the particle hit. Most of the detected glitches are from Galactic protons incident on the die frame supporting the micro-machined bolometric detectors. In the Planck orbit at L2, the particle flux is around 5 cm-2 s-1 and is dominated by protons incident on the spacecraft with energy >39 MeV, at a rate of typically one event per second per detector. Different categories of glitches have different signatures in the time stream. Two of the glitch types have a low amplitude component that decays over nearly 1?s. This component produces excess noise if not properly removed from the time-ordered data. We have used a glitch detection and subtraction method based on the joint fit of population templates. The application of this novel glitch subtraction method removes excess noise from the time streams. Using realistic simulations, we find that this method does not introduce signal bias into the Planck data.es_ES
dc.format.extent23 p.es_ES
dc.language.isoenges_ES
dc.publisherEDP Scienceses_ES
dc.rights© ESO 2014es_ES
dc.sourceA&A 571, A10 (2014)es_ES
dc.titlePlanck 2013 results. X. HFI energetic particle effects: characterization, removal, and simulationes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.relation.publisherVersionhttps://doi.org/10.1051/0004-6361/201321577es_ES
dc.rights.accessRightsopenAccesses_ES
dc.identifier.DOI10.1051/0004-6361/201321577es_ES
dc.type.versionpublishedVersiones_ES


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record