    The effect of impurities on the evolution of the melting front analyzed in a two-dimensional representation for the eutectic Pt–C

    Ver/Abrir
    TheEffectofImpuritie ... (650.8Kb)
    Identificadores
    URI: http://hdl.handle.net/10902/9739
    DOI: 10.1007/s10765-014-1700-7
    ISSN: 0195-928X
    ISSN: 1572-9567
    Compartir
    RefworksMendeleyBibtexBase
    Estadísticas
    Ver Estadísticas
    Google Scholar
    Registro completo
    Mostrar el registro completo DC
    Autoría
    Castro Alonso, Pablo BernardoAutoridad Unican; Bloembergen, Pieter; Dong, Wei
    Fecha
    2014-07
    Derechos
    © Springer. The final publication is available at Springer via https://doi.org/10.1007/s10765-014-1700-7
    Publicado en
    International Journal of Thermophysics, 2014, 35(6), 1378–1390
    Editorial
    Springer
    Enlace a la publicación
    https://doi.org/10.1007/s10765-014-1700-7
    Palabras clave
    High-temperature fixed point
    Impurity distribution
    Melting front
    Resumen/Abstract
    The paper discusses the effect of two-front melting on the liquidus temperature of the eutectic Pt–C and the eutectic temperature of the system in its pure state. This influence factor has not been considered thus far in the uncertainty budget associated with the assignment of thermodynamic temperatures to the eutectics Co–C (1597.15 K), Pt–C (2011.05 K), and Re–C (2747.35 K), selected in the European Metrology Research Programme project Implementing the New Kelvin. For Pt–C, simulation of the effect of two-front melting on the melting process has been done before in a 1D analytical model, and this formed the starting point to the present study. In this study the melting process is analyzed by means of a 2D axisymmetrical finite-volume model. In the model, freezing and melting are considered for an impure ingot and for a pure ingot. As to the impure ingot, the impurity concentrations are the concentrations met in current practice of the realization of the high-temperature reference fixed point, but formulated in terms of an effective concentration and associated effective distribution coefficient k<1, related to a Scheil fit to the melting curve at given melting conditions as measured for the eutectic Pt–C. Heat injection rates for melting varied from 15000 W·m-2 down to 3000 W·m-2. In any case for the impure system, two melting fronts are showing up. For the pure system, only one melting front is generated, traveling from the outside of the ingot toward its inside.
    Colecciones a las que pertenece
    • D19 Artículos [94]

    UNIVERSIDAD DE CANTABRIA

    Repositorio realizado por la Biblioteca Universitaria utilizando DSpace software
    Contacto | Sugerencias
    Metadatos sujetos a:licencia de Creative Commons Reconocimiento 4.0 España
     

     

    Listar

    Todo UCreaComunidades y coleccionesFecha de publicaciónAutoresTítulosTemasEsta colecciónFecha de publicaciónAutoresTítulosTemas

    Mi cuenta

    AccederRegistrar

    Estadísticas

    Ver Estadísticas
    Sobre UCrea
    Qué es UcreaGuía de autoarchivoArchivar tesisAcceso abiertoGuía de derechos de autorPolítica institucional
    Piensa en abierto
    Piensa en abierto
    Compartir

    UNIVERSIDAD DE CANTABRIA

    Repositorio realizado por la Biblioteca Universitaria utilizando DSpace software
    Contacto | Sugerencias
    Metadatos sujetos a:licencia de Creative Commons Reconocimiento 4.0 España