Mostrar el registro sencillo

dc.contributor.authorMennella, Aniello
dc.contributor.authorBersanelli, Marco
dc.contributor.authorButler, Reginald Christopher
dc.contributor.authorCuttaia, Francesco
dc.contributor.authorD'Arcangelo, Ocleto
dc.contributor.authorDavis, Richard J.
dc.contributor.authorFrailis, Marco
dc.contributor.authorGaleotta, Samuele
dc.contributor.authorGregorio, Anna
dc.contributor.authorLawrence, Charles R.
dc.contributor.authorLeonardi, Rodrigo
dc.contributor.authorAja Abelán, Beatriz 
dc.contributor.authorArtal Latorre, Eduardo 
dc.contributor.authorBernardino Santos, Teodoro
dc.contributor.authorFuente Rodríguez, Luisa María de la 
dc.contributor.authorMartínez González, Enrique
dc.contributor.authorMediavilla Sánchez, Ángel 
dc.contributor.authorPascual Gutiérrez, Juan Pablo 
dc.contributor.authorSalmón, María J.
dc.contributor.authorLowe, Stuart
dc.contributor.otherUniversidad de Cantabriaes_ES
dc.date.accessioned2012-11-06T09:36:10Z
dc.date.available2012-11-06T09:36:10Z
dc.date.issued2010-09-15
dc.identifier.issn0004-6361
dc.identifier.issn1432-0746
dc.identifier.urihttp://hdl.handle.net/10902/927
dc.description.abstractWe present the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters characterise the instrument response and constitute our optimal pre-launch knowledge of the LFI scientific performance. The LFI shows excellent 1/f stability and rejection of instrumental systematic effects; its measured noise performance shows that LFI is the most sensitive instrument of its kind. The calibration parameters will be updated during flight operations until the end of the mission.es_ES
dc.description.sponsorshipThe Planck-LFI project is developed by an Interntional Consortium lead by Italy and involving Canada, Finland, Germany, Norway, Spain, Switzerland, UK, USA. The Italian contribution to Planck is supported by the Italian Space Agency (ASI). The work in this paper has been supported by in the framework of the ASI-E2 phase of the Planck contract. The US Planck Project is supported by the NASA Science Mission Directorate. In Finland, the Planck-LFI 70 GHz work was supported by the Finnish Funding Agency for Technology and Innovation (Tekes)
dc.format.extent16 p.es_ES
dc.language.isoenges_ES
dc.publisherEDP Scienceses_ES
dc.rights© ESO 2010*
dc.sourceAstronomy and Astrophysics, 2010, 520, A5.es_ES
dc.subject.otherCosmic microwave background
dc.subject.otherTelescopes
dc.subject.otherSpace vehicles: instruments
dc.subject.otherInstrumentation: detectors
dc.subject.otherInstrumentation: polarimeters
dc.subject.otherSubmillimeter: general
dc.titlePlanck pre-launch status: Low Frequency Instrument calibration and expected scientific performancees_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.relation.publisherVersionhttp://dx.doi.org/10.1051/0004-6361/200912849
dc.rights.accessRightsopenAccesses_ES
dc.identifier.DOI10.1051/0004-6361/200912849
dc.type.versionpublishedVersiones_ES


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo