dc.contributor.authorSánchez, Alberto
dc.contributor.authorCastro, Ángel de
dc.contributor.authorLópez Martín, Víctor Manuel
dc.contributor.authorAzcondo Sánchez, Francisco Javier 
dc.contributor.authorGarrido, Javier
dc.contributor.otherUniversidad de Cantabriaes_ES
dc.date.accessioned2016-01-27T08:17:41Z
dc.date.available2016-01-27T08:17:41Z
dc.date.issued2014
dc.identifier.issn0885-8993
dc.identifier.issn1941-0107
dc.identifier.urihttp://hdl.handle.net/10902/7964
dc.description.abstractTraditional digital power factor correction (PFC) uses three sensors to measure the input and output voltages and the input current. Each sensor, especially the input current one, increases the cost of the system and generates power losses in case of resistive sensors. This paper presents a controller for boost PFC converters. It uses precalculated duty cycles generated offline, and applies them to the switch. In order to control the converter with nonnominal conditions, just one analog-to-digital converter (ADC) is used, whichmeasures the output voltage.Measuring the average and the ripple of the output voltage with this ADC, the controller takes compensation action for changes in the input voltage but also in the load of the converter. The average value is used to control the input voltage changes, while the ripple value is used to control load changes. These two loops present low frequency bandwidth, so the ADC and the whole system can be low cost. Finally, a comparator is used to detect the zero-crossing of the input voltage, so the precalculated values are synchronized with the ac mains. In this way, the converter only uses one ADC and one comparator, both with lowbandwidth. Results showthat high power factor and normative compliance are reached, even under nonnominal conditions.es_ES
dc.format.extent11 p.es_ES
dc.language.isoenges_ES
dc.publisherInstitute of Electrical and Electronics Engineers Inc.es_ES
dc.rights© 2014 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.es_ES
dc.sourceIEEE Transactions on Power Electronics, Vol. 29, N. 2, February 2014, DOI:10.1109/TPEL.2013.2256931es_ES
dc.titleSingle ADC Digital PFC Controller Using Precalculated Duty Cycleses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.relation.publisherVersionhttp://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6494338es_ES