    Analysis of a real case of ampacity management in a 132 kV network integrating high rates of wind energy

    Ver/Abrir
    Analysis of a real.pdf (225.8Kb)
    Identificadores
    URI: http://hdl.handle.net/10902/7671
    ISBN: 978-84-606-5436-0
    ISSN: 2172-038X
    Compartir
    RefworksMendeleyBibtexBase
    Estadísticas
    Ver Estadísticas
    Google Scholar
    Registro completo
    Mostrar el registro completo DC
    Autoría
    Madrazo Maza, AlfredoAutoridad Unican; González, A.; Martínez Torre, RaquelAutoridad Unican; Domingo Fernández, RodrigoAutoridad Unican; Mañana Canteli, MarioAutoridad Unican; Arroyo Gutiérrez, AlbertoAutoridad Unican; Castro Alonso, Pablo BernardoAutoridad Unican; Silió Salcines, DelfínAutoridad Unican; Lecuna Tolosa, RamónAutoridad Unican
    Fecha
    2015-04
    Derechos
    © European Association for the Development of Renewable Energies, Environment and Power Quality (EA4EPQ)
    Publicado en
    Renewable Energy & Power Quality Journal, 2015, 1(13), 797-800
    International Conference on Renewable Energies and Power Quality (ICREPQ’15), La Coruña
    Editorial
    European Association for the Development of Renewable Energies, Environment and Power Quality (EA4EPQ)
    Palabras clave
    Wind energy
    Ampacity
    Grid integration
    Dynamic management
    Resumen/Abstract
    The grid integration of renewable energy, and particularly in Spain, supposes an important problem to deal with for Distributor System Operators (DSO). Most of the times Wind Energy Farms are located in places that are far away from the transmission networks so they have to be integrated into distribution networks that are frequently next to their static rate. Current regulations make almost impossible to build new overhead lines so the increase of the capacity of the existing lines is a new target for the DSO. One of the developed options to solve this issue is the dynamic management of the network. This paper is devoted to the analysis of a real case of ampacity management in a 132 kV overhead line placed in a high-wind generation area. The obtained results show that this approach can increase the lines capacity in a significant percentage.
    Colecciones a las que pertenece
    • D19 Congresos [94]
    • D19 Proyectos de investigación [102]

    UNIVERSIDAD DE CANTABRIA

    Repositorio realizado por la Biblioteca Universitaria utilizando DSpace software
    Contacto | Sugerencias
    Metadatos sujetos a:licencia de Creative Commons Reconocimiento 4.0 España
     

     

    Listar

    Todo UCreaComunidades y coleccionesFecha de publicaciónAutoresTítulosTemasEsta colecciónFecha de publicaciónAutoresTítulosTemas

    Mi cuenta

    AccederRegistrar

    Estadísticas

    Ver Estadísticas
    Sobre UCrea
    Qué es UcreaGuía de autoarchivoArchivar tesisAcceso abiertoGuía de derechos de autorPolítica institucional
    Piensa en abierto
    Piensa en abierto
    Compartir

    UNIVERSIDAD DE CANTABRIA

    Repositorio realizado por la Biblioteca Universitaria utilizando DSpace software
    Contacto | Sugerencias
    Metadatos sujetos a:licencia de Creative Commons Reconocimiento 4.0 España