    Long-term analysis of clogging and oil bio-degradation in a System of Catchment, Pre-treatment and Treatment (SCPT)

    Ver/Abrir
    Long-term analysis of ... (1.299Mb)
    Identificadores
    URI: http://hdl.handle.net/10902/7145
    DOI: 10.1016/j.jhazmat.2010.10.034
    ISSN: 0304-3894
    ISSN: 1873-3336
    Compartir
    RefworksMendeleyBibtexBase
    Estadísticas
    Ver Estadísticas
    Google Scholar
    Registro completo
    Mostrar el registro completo DC
    Autoría
    Fernandez-Barrera, Andrés H.; Castro Fresno, DanielAutoridad Unican; Rodríguez Hernández, JorgeAutoridad Unican; Vega Zamanillo, AngelAutoridad Unican
    Fecha
    2011
    Derechos
    © 2011. This manuscript version is made available under the CC-BY-NC-ND 4.0 license
    Publicado en
    Journal of Hazardous Materials, 185 (2-3), 1221-1227.
    Editorial
    Elsevier
    Palabras clave
    Best Management Practice
    Geotextile
    Water quality
    Up-flow filtration
    Oil bio-degradation
    Resumen/Abstract
    Runoff contamination has motivated the development of different systems for its treatment in order to decrease the pollutant load that is discharged into natural water bodies. In the long term, these systems may undergo operational problems. This paper presents the results obtained in a laboratory study with a 1:1 scale prototype of a System of Catchment, Pre-treatment and Treatment (SCPT) of runoff waters. The analysis aims to establish the operational behaviour of the SCPT in the long term with respect to oil degradation and hydraulic conductivity in the geotextile filter. It is concluded that bio-degradation processes take place inside the SCPT and that hydraulic conductivity of the geotextile filtration system decreases slowly with successive simulated runoff events.
    Colecciones a las que pertenece
    • D09 Artículos [449]
    • D09 Proyectos de investigación [219]

    UNIVERSIDAD DE CANTABRIA

    Repositorio realizado por la Biblioteca Universitaria utilizando DSpace software
    Contacto | Sugerencias
    Metadatos sujetos a:licencia de Creative Commons Reconocimiento 4.0 España
     

     

    Listar

    Todo UCreaComunidades y coleccionesFecha de publicaciónAutoresTítulosTemasEsta colecciónFecha de publicaciónAutoresTítulosTemas

    Mi cuenta

    AccederRegistrar

    Estadísticas

    Ver Estadísticas
    Sobre UCrea
    Qué es UcreaGuía de autoarchivoArchivar tesisAcceso abiertoGuía de derechos de autorPolítica institucional
    Piensa en abierto
    Piensa en abierto
    Compartir

    UNIVERSIDAD DE CANTABRIA

    Repositorio realizado por la Biblioteca Universitaria utilizando DSpace software
    Contacto | Sugerencias
    Metadatos sujetos a:licencia de Creative Commons Reconocimiento 4.0 España