Mostrar el registro sencillo

dc.contributor.authorJáuregui Misas, César
dc.contributor.authorQuintela Incera, Antonio 
dc.contributor.authorEchevarría Cuenca, Juan 
dc.contributor.authorQuintela Incera, María Ángeles 
dc.contributor.authorCobo García, Adolfo 
dc.contributor.authorLópez Higuera, José Miguel 
dc.contributor.otherUniversidad de Cantabriaes_ES
dc.date.accessioned2014-05-09T06:56:37Z
dc.date.available2014-05-09T06:56:37Z
dc.date.issued2003-03-13
dc.identifier.issn1996-756X
dc.identifier.issn0277-786X
dc.identifier.urihttp://hdl.handle.net/10902/4589
dc.description.abstractStructural health and behavior monitoring have always been both a common concern and need in civil engineering. Several classical approaches have been given to this problem including the widley used strain gauges as well as the topographic measurements. These two techniques are almost always used to monitor the behavior of the structures whereas the health monitoring is accomplished by a simple periodic visual inspection. These approaches present serious problems that limit their practical use in real structures such as: lack of fiability, long-term drift, impossibility of full-time measurements, or lack of thoroughness. Centering the discussion in the strain gauges, for being the most representative of the classical civil engineering monitoring methods, it must be said that due to their electric nature they are exposed to both electromagnetic interference and corrosion. The latter greatly reduces their operating life time pushing it typically to less than one year after installation. That is whey new ways of monitoring civil structures were looked for, and that is how photonic fiber sensing came up. Characteristics shared by all fiber senors are their electromagnetic immunity for being manufactured using a dielectric material, low weight, small size, and compatibility with construction materials. As can be seen these inherent characteristics make them very suitable for their use in civil engineering structures. An example of a quasi-distributed transducer is presented in this communication. First the theoretical fundamentals of the transducer and its behavior is explained, and an in-field experiment consisting on monitoring a bridge is described and its results reported.es_ES
dc.format.extent7 p.es_ES
dc.language.isoenges_ES
dc.publisherSPIE Society of Photo-Optical Instrumentation Engineerses_ES
dc.rights© 2003 Society of Photo-Optical Instrumentation Engineers. One print or electronic copy may be made for personal use only. Systematic electronic or print reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited.es_ES
dc.sourceProceedings of SPIE, 2003, vol. 4763, 233-239es_ES
dc.sourceEuropean Workshop on Smart Structures in Engineering and Technology, Giens, France, 2002es_ES
dc.subject.otherFiber Bragg gratings
dc.subject.otherTransducers
dc.subject.otherCivil engineering
dc.subject.otherCorrosion
dc.subject.otherDielectrics
dc.subject.otherElectromagnetic interference
dc.subject.otherOptical inspection
dc.titleBridge sensing using a fiber Bragg grating quasi-distributed transducer: in-field resultses_ES
dc.typeinfo:eu-repo/semantics/conferenceObjectes_ES
dc.relation.publisherVersionhttp://dx.doi.org/10.1117/12.508743es_ES
dc.rights.accessRightsopenAccesses_ES
dc.identifier.DOI10.1117/12.508743
dc.type.versionpublishedVersiones_ES


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo