Mostrar el registro sencillo

dc.contributor.authorCastro Alonso, Pablo Bernardo 
dc.contributor.authorMacHin G.
dc.contributor.authorVillamañan M.A.
dc.contributor.authorLowe D.
dc.contributor.otherUniversidad de Cantabriaes_ES
dc.date.accessioned2025-09-29T07:49:41Z
dc.date.available2025-09-29T07:49:41Z
dc.date.issued2011-08
dc.identifier.issn0195-928X
dc.identifier.issn1572-9567
dc.identifier.urihttps://hdl.handle.net/10902/37492
dc.description.abstractHigh-temperature fixed points (HTFPs) based on eutectic and peritectic reactions of metals and carbon are likely to become, in the near term, reference standards at high temperatures. Typically for radiation thermometry applications, these HTFPs are generally formed of a graphite crucible, with a reentrant well, an included 120° cone, and a nominal aperture of 3 mm. It is important to quantify the temperature drop at the back wall of the cavity, and to understand the influence of the crucible configuration and furnace conditions on this drop. In order to study these influences, three different situations have been modeled by means of the finite volume method for numerical analysis. The first investigates the influence of the furnace temperature profile on the temperature drop by simulating four different furnace conditions. The other two study variations in the crucible configuration, namely, the thickness of the graphite back wall and the length of the blackbody tube.es_ES
dc.format.extent13 p.es_ES
dc.language.isoenges_ES
dc.publisherSpringeres_ES
dc.rights© 2011, Springer Science Business Media, LLC. This version of the article has been accepted for publication, after peer review (when applicable) and is subject to Springer Nature's AM terms of use, but is not the Version of Record and does not reflect post-acceptance improvements, or any corrections. The Version of Record is available online at: ttps://doi.org/10.1007/s10765-011-1019-6es_ES
dc.sourceInternational Journal of Thermophysics, 2011, 32(7-8), 1773 - 1785es_ES
dc.subject.otherBack walles_ES
dc.subject.otherBlackbody tubees_ES
dc.subject.otherCruciblees_ES
dc.subject.otherFixed pointes_ES
dc.subject.otherFurnace temperature profilees_ES
dc.titleCalculation of the temperature drop for high-temperature fixed points for different furnace conditionses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.relation.publisherVersionttps://doi.org/10.1007/s10765-011-1019-6es_ES
dc.rights.accessRightsopenAccesses_ES
dc.identifier.DOI10.1007/s10765-011-1019-6
dc.type.versionacceptedVersiones_ES


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo