Mostrar el registro sencillo

dc.contributor.authorSetién Dodero, Fernando
dc.contributor.authorFanjul Vélez, Félix 
dc.contributor.authorArce Diego, José Luis 
dc.contributor.otherUniversidad de Cantabriaes_ES
dc.date.accessioned2025-04-01T16:10:31Z
dc.date.available2025-04-01T16:10:31Z
dc.date.issued2024
dc.identifier.isbn979-8-3503-7149-9
dc.identifier.otherPID2021-127691OB-I00es_ES
dc.identifier.urihttps://hdl.handle.net/10902/36153
dc.description.abstractAtrial Fibrillation (AF) is a heart rhythm disorder characterized by rapid and irregular atrial contractions, which can increase the risk of stroke and decrease patients' quality of life. One of the main techniques to treat AF is RF catheter ablation, which involves electrically isolating the pulmonary veins from the rest of the atrium, based on point lesions surrounding the veins. There is still discussion in the community as to what is the optimal interlesion distance to improve the long-term results of AF ablation. A Python tool has been developed that, starting from the AF ablation procedure data, finds the optimal sequence of ablations surrounding the pulmonary veins and thus can calculate the distance between the entire sequence of lesions. The automated algorithm proved to be effective in most cases and in almost all cases semi-automatically. The work provides a tool for the community that can help to optimize AF ablation. In the future, the algorithm could be improved to be 100% automatic, although right now it is already useful and several clinical studies are underway using this tool.es_ES
dc.description.sponsorshipGrant PID2021-127691OB-I00 financed by MCIN/ AEI/10.13039/501100011033/, and by FEDER a way to make Europees_ES
dc.format.extent4 p.es_ES
dc.language.isoenges_ES
dc.publisherInstitute of Electrical and Electronics Engineers, Inc.es_ES
dc.rights© 2024 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.es_ES
dc.source46th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Orlando, 2024, 3820-3823es_ES
dc.subject.otherAtrial fibrillationes_ES
dc.subject.otherRF ablationes_ES
dc.subject.otherInter-lesion distancees_ES
dc.titleValidation of an algorithm for automatic calculation of inter-lesion distance in radiofrequency catheter ablation of atrial fibrillationes_ES
dc.typeinfo:eu-repo/semantics/conferenceObjectes_ES
dc.relation.publisherVersionhttps://doi.org/10.1109/EMBC53108.2024.10781948es_ES
dc.rights.accessRightsopenAccesses_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2021-2023/PID2021-127691OB-I00/ES/CRIBADO DIAGNOSTICO DE MICROORGANISMOS MEDIANTE MICROSCOPIA AVANZADA E INTELIGENCIA ARTIFICIAL EN PATOLOGIAS HUMANAS/es_ES
dc.identifier.DOI10.1109/EMBC53108.2024.10781948
dc.type.versionacceptedVersiones_ES


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo