• Mi UCrea
    Ver ítem 
    •   UCrea
    • UCrea Investigación
    • Departamento de Ingeniería Informática y Electrónica
    • D30 Artículos
    • Ver ítem
    •   UCrea
    • UCrea Investigación
    • Departamento de Ingeniería Informática y Electrónica
    • D30 Artículos
    • Ver ítem
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Ferroresonance phenomena in medium-voltage isolated neutral grids: a case study

    Ver/Abrir
    FerroresonancePhenom ... (6.353Mb)
    Identificadores
    URI: https://hdl.handle.net/10902/35231
    DOI: 10.1049/iet-rpg.2018.5231
    ISSN: 1752-1416
    Compartir
    RefworksMendeleyBibtexBase
    Estadísticas
    Ver Estadísticas
    Google Scholar
    Registro completo
    Mostrar el registro completo DC
    Autoría
    Martínez Torre, RaquelAutoridad Unican; Mañana Canteli, MarioAutoridad Unican; Rodríguez Alonso, José Iván; Álvarez, Marcos; Arroyo Gutiérrez, AlbertoAutoridad Unican; Bayona Blanco, EduardoAutoridad Unican; Azcondo Sánchez, Francisco JavierAutoridad Unican; Pigazo López, AlbertoAutoridad Unican; Francisco, Cuartas
    Fecha
    2019-01
    Derechos
    Alojado según Resolución CNEAI 9/12/24 (ANECA) © The Institution of Engineering and Technology 2018
    Publicado en
    IET Renewable Power Generation, 2019, 13(1), 209-214
    Editorial
    The Institution of Engineering and Technology
    Enlace a la publicación
    https://doi.org/10.1049/iet-rpg.2018.5231
    Resumen/Abstract
    Power quality events associated with the occurrence of ferroresonances in medium voltage (MV) isolated-neutral distribution power systems are well known but they still happen in nowadays grids. This work deals with the study of ferroresonance events in a distribution grid region characterised by having distributed generators and being lightly loaded. The study shows that well-known solutions, i.e. voltage transformer damping, are difficult to apply due to the legal considerations and, alternatively, the distribution system operator can take actions to minimise their effect on the distribution system. The data provided and the obtained results correspond to a three-year measurement campaign at a real MV isolated-neutral distribution power system. The measurements and analysis given allow reaching general conclusions about the distribution system operation oriented to minimise the effect of ferroresonances.
    Colecciones a las que pertenece
    • D30 Artículos [97]

    UNIVERSIDAD DE CANTABRIA

    Repositorio realizado por la Biblioteca Universitaria utilizando DSpace software
    Contacto | Sugerencias
    Metadatos sujetos a:licencia de Creative Commons Reconocimiento 4.0 España
     

     

    Listar

    Todo UCreaComunidades y coleccionesFecha de publicaciónAutoresTítulosTemasEsta colecciónFecha de publicaciónAutoresTítulosTemas

    Mi cuenta

    AccederRegistrar

    Estadísticas

    Ver Estadísticas
    Sobre UCrea
    Qué es UcreaGuía de autoarchivoArchivar tesisAcceso abiertoGuía de derechos de autorPolítica institucional
    Piensa en abierto
    Piensa en abierto
    Compartir

    UNIVERSIDAD DE CANTABRIA

    Repositorio realizado por la Biblioteca Universitaria utilizando DSpace software
    Contacto | Sugerencias
    Metadatos sujetos a:licencia de Creative Commons Reconocimiento 4.0 España