dc.contributor.author | Bayona Blanco, Eduardo | |
dc.contributor.author | Azcondo Sánchez, Francisco Javier | |
dc.contributor.author | Brañas Reyes, Christian | |
dc.contributor.author | Díaz Rodríguez, Francisco Javier | |
dc.contributor.author | Martínez Torre, Raquel | |
dc.contributor.author | Mañana Canteli, Mario | |
dc.contributor.author | Mínguez, Rafael | |
dc.contributor.author | Rodríguez Alonso, José Iván | |
dc.contributor.author | Pigazo López, Alberto | |
dc.contributor.other | Universidad de Cantabria | es_ES |
dc.date.accessioned | 2025-01-29T12:37:11Z | |
dc.date.available | 2025-01-29T12:37:11Z | |
dc.date.issued | 2019-01 | |
dc.identifier.issn | 1752-1416 | |
dc.identifier.uri | https://hdl.handle.net/10902/35229 | |
dc.description.abstract | The occurrence of ferroresonances, due to the presence of voltage transformers in isolated-neutral in medium-voltage (MV) distribution grids, results in overvoltages and overcurrents that may damage the connected equipment. To prevent this phenomenon, the protection windings of the MV transformers have to be properly loaded for damping purposes. Mitigation equipment based on resistors, passive/active circuits and static converters have been proposed in the literature. This study proposes a new variety of mitigation equipment based on very simple power electronic converters operated as configurable resistor emulators. The proposed approach is evaluated theoretically and validated experimentally. A resistor emulator proof of concept is designed and applied for damping ferroresonances due to the occurrence of line-to-ground faults in isolated-neutral MV distribution power systems. | es_ES |
dc.description.sponsorship | This work was supported by the Spanish government and FEDER funds of the European Union under RETOS RTC-2015-4176-3, Innovation in the automation of the isolated neutral distribution.The authors also acknowledge the support received from Viesgo S.L. | es_ES |
dc.format.extent | 8 | es_ES |
dc.language.iso | eng | es_ES |
dc.publisher | The Institution of Engineering and Technology | es_ES |
dc.rights | © The Institution of Engineering and Technology 2018 | es_ES |
dc.source | IET Renewable Power Generation, 2019, 13(1), 201-208 | es_ES |
dc.title | Electronic resistor emulators forferroresonance damping in MV transformers | es_ES |
dc.type | info:eu-repo/semantics/article | es_ES |
dc.relation.publisherVersion | https://doi.org/10.1049/iet-rpg.2018.5242 | es_ES |
dc.rights.accessRights | openedAccess | es_ES |
dc.identifier.DOI | 10.1049/iet-rpg.2018.5242 | |
dc.type.version | publishedVersion | es_ES |