Mostrar el registro sencillo

dc.contributor.advisorRuiz Fuertes, Javier 
dc.contributor.advisorAguado Menéndez, Fernando 
dc.contributor.authorPrendes Vila, Tania
dc.contributor.otherUniversidad de Cantabriaes_ES
dc.date.accessioned2024-10-14T17:25:22Z
dc.date.available2024-10-14T17:25:22Z
dc.date.issued2024-07
dc.identifier.urihttps://hdl.handle.net/10902/34251
dc.description.abstractEn este trabajo se ha resuelto la estructura cristalina de una muestra de formiato de cobre (II) de guanidinio, [C(NH₂)₃]Cu(HCOO)₃, a partir de datos de difracción de rayos X en monocristal medidos en línea ID15B del sincrotrón ESRF, a presión y temperatura ambiente. Para ello, se ha seguido un proceso de análisis de las imágenes de difracción de rayos X utilizando el software CrysAlis y se ha realizado su correspondiente refinamiento haciendo uso del software WinGX. A su vez, se han comparado los resultados con los obtenidos a partir de datos procedentes de un difractómetro de cuatro círculos equipado con un tubo de Mo, estudiando las diferencias en los dispositivos experimentales, las limitaciones de sus configuraciones y su efecto en la resolución de estructuras. Finalmente, se han realizado medidas de absorción óptica a presión ambiente para relacionar las propiedades estructurales estudiadas con las propiedades ópticas del material. En particular, se analizaron las bandas correspondientes a las transiciones d → d∗ internas del Cu²⁺, dadas por los desdoblamientos de los niveles energéticos inducidos por la presencia de la distorsión Jahn-Teller en el cristal.es_ES
dc.description.abstractThe crystal structure of a sample of guanidinium copper (II) formate, [C(NH₂)₃]Cu(HCOO)₃, has been solved using single-crystal X-ray diffraction data obtained at the ESRF synchrotron, ID15B beamline, under ambient pressure and temperature conditions. This was achieved through analysis of X-ray diffraction images using the CrysAlis software, followed by refinement using WinGX. Furthermore, the results obtained were compared with those from data measured on a fourcircle diffractometer, exploring differences in experimental setups, their limitations and the effect on structural solutions. Lastly, optical absorption measurements at ambient pressure were conducted to correlate the studied structural properties with the optical properties of the material. Bands corresponding to internal d → d∗ transitions of Cu²⁺ were analyzed, paying attention to the energy level splittings due to the Jahn-Teller distortion present in the crystal.es_ES
dc.format.extent76 p.es_ES
dc.language.isospaes_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internationales_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.titleResolución estructural del formiato de cobre (II) de guanidinio a partir de datos de difracción de rayos X de monocristal en sincrotrón: comparación con datos de difractómetro de laboratorioes_ES
dc.title.alternativeStructural resolution of guanidinium copper (II) formate from synchrotron single-crystal X-ray diffraction data: comparison with laboratory diffractometer dataes_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
dc.rights.accessRightsopenAccesses_ES
dc.description.degreeGrado en Físicaes_ES


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo

Attribution-NonCommercial-NoDerivatives 4.0 InternationalExcepto si se señala otra cosa, la licencia del ítem se describe como Attribution-NonCommercial-NoDerivatives 4.0 International