Effect of recycled foundry sand on the workability and mechanical properties of mortar
Ver/ Abrir
Registro completo
Mostrar el registro completo DCAutoría
García Del Ángel, Gilberto de Jesús; Sainz-Aja Guerra, José Adolfo



Fecha
2023Derechos
© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.
Publicado en
Applied Sciences, 2023, 13(6), 3436
Editorial
MDPI
Palabras clave
Used foundry sand
Mortar
Workability
Mechanical properties
Wear resistance
W/C ratio
Resumen/Abstract
Modern society requires a large number of metal components manufactured by sand casting, which involves the generation of a waste product known as Used Foundry Sand (UFS), of which approximately 100 Mt are generated on an annual basis. Virtually all UFS is currently landfilled, despite the economic and environmental cost overruns that this entails. Here, the recovery of UFS as fine aggregates for the manufacture of concrete is proposed. Since the presence of UFS will mainly affect the mortar that binds the aggregates in the manufacture of concrete, it was decided to isolate this fraction and study only the effect of UFS in mortars. This study evaluated a total of 32 different mixes combining different W/C ratios varying between 0.5 and 0.7 with 5 replacement ratios of natural sand by UFS: 0, 25, 50, 75 and 100%, respectively. The combined effect was evaluated of the W/C ratio and the replacement ratio on the workability, physical properties, mechanical properties, mechanical durability, and microstructure of the mortars. The incorporation of UFS decreases the
workability of the mortars due to the absorption of the residue. For the physical properties of the mortars, density decreased and porosity and absorption increased at all replacement percentages. Flexural and compressive strength decreased when the replacement percentage was higher than 25 wt.%. In terms of mechanical durability, the mortars with UFS showed abrasion marks within the limits of the EN-1338 standard. From the results obtained, it is possible to conclude that the mortars with UFS require a higher amount of water. Therefore, while small replacement levels lead to a slight improvement in the mechanical properties, this trend breaks down for high replacement levels due to the negative effect of the high W/C ratios required. The authors recommend that for replacements higher than 25 wt.% of UFS, the W/C ratio has to be taken into consideration to obtain the same workability as the control mortar, although this decreases the mechanical properties.
Colecciones a las que pertenece
- D03 Artículos [296]