dc.contributor.author | Celaya Gonzalez, Santiago | |
dc.contributor.author | Rábago Gómez, Daniel | |
dc.contributor.author | Fuente Merino, Ismael | |
dc.contributor.author | Quindós López, Luis | |
dc.contributor.author | Bon Carreras, Núria | |
dc.contributor.author | Valero Castell, María Trinidad | |
dc.contributor.author | Gutiérrez Villanueva, José Luis | |
dc.contributor.author | Sainz Fernández, Carlos | |
dc.contributor.other | Universidad de Cantabria | es_ES |
dc.date.accessioned | 2024-01-30T15:27:18Z | |
dc.date.available | 2024-01-30T15:27:18Z | |
dc.date.issued | 2018-11 | |
dc.identifier.issn | 0144-8420 | |
dc.identifier.issn | 1742-3406 | |
dc.identifier.uri | https://hdl.handle.net/10902/31325 | |
dc.description.abstract | Radon-222, a naturally occurring radioactive gas, responsible together with its progeny of around 50% of the average effective dose received by the population, has not been regulated by law until the recent Directive 2013/51 /Euratom. Its transposition into Spanish legislation was made in the recent RD 314/2016, which sets at limit value of 500 Bq l¯¹ for radon-222 in water for human consumption. Intercomparison exercises, such as those carried out by IPROMA SL and the Laboratory of Environmental Radioactivity of the Cantabria University (LARUC) in November 2015 and December 2016, represent the most useful tool available for detecting problems and taking corrective actions necessary for an efficient measurement by part of the laboratories. The participants in these exercises used three techniques: liquid scintillation counting, gamma spectrometry and desorption followed by ionisation chamber detection. | es_ES |
dc.format.extent | 27 p. | |
dc.language.iso | eng | es_ES |
dc.publisher | Oxford University Press | es_ES |
dc.rights | © Oxford University Press. This is a pre-copy-editing, author-produced PDF of an article accepted for publication in Radiation Protection Dosimetry following peer review. The definitive publisher-authenticated version Radiation Protection Dosimetry, 2018, 181(4), 343-349 is available online at: https://dx.doi.org/10.1093/rpd/ncy033 | |
dc.source | Radiation Protection Dosimetry, 2018, 181(4), 343-349 | es_ES |
dc.subject.other | Radon | |
dc.subject.other | Water | |
dc.subject.other | Intercomparison | |
dc.subject.other | Liquid scintillation counting | |
dc.subject.other | Gamma spectrometry | |
dc.subject.other | 46 ionisation chamber | |
dc.title | A simple national intercomparison of radon in water | es_ES |
dc.type | info:eu-repo/semantics/article | es_ES |
dc.relation.publisherVersion | https://dx.doi.org/10.1093/rpd/ncy033 | es_ES |
dc.rights.accessRights | openAccess | es_ES |
dc.identifier.DOI | 10.1093/rpd/ncy033 | |
dc.type.version | acceptedVersion | es_ES |