Mostrar el registro sencillo

dc.contributor.authorOria Alonso, Carmela 
dc.contributor.authorCarrascal Vaquero, Isidro Alfonso 
dc.contributor.authorFerreño Blanco, Diego 
dc.contributor.authorMéndez Gutiérrez, Cristina 
dc.contributor.authorOrtiz Fernández, Alfredo 
dc.contributor.otherUniversidad de Cantabriaes_ES
dc.date.accessioned2023-08-29T08:15:55Z
dc.date.available2023-08-29T08:15:55Z
dc.date.issued2023-10
dc.identifier.issn2352-3409
dc.identifier.otherPID2019-107126RB-C22es_ES
dc.identifier.urihttps://hdl.handle.net/10902/29772
dc.description.abstractThe structural elements within power transformers are commonly constructed from high-density pressboard, chosen for its favourable mechanical and dielectric properties. Among these elements are the spacers employed in the windings of transformers, which endure compressive loading during operation. The spacers are immersed in dielectric fluid and exposed to high temperatures and chemical reactions over the transformer's lifespan, resulting in the degradation of their dielectric and mechanical properties. The mechanical integrity of the power transformer significantly relies on these factors; hence, it is imperative to comprehend how ageing deteriorates the mechanical response of the high-density pressboard. The present article presents experimental data on the compressive mechanical properties of a commercially available high-density pressboard, commonly employed in power transformer spacers, under various ageing conditions (induced through accelerated thermal ageing and assessed by the degree of polymerisation). These data hold potential for diverse applications. They can enhance the existing comprehension of the mechanical behaviour and degradation mechanisms of cellulosic insulation in power transformers and provide reference benchmarks for comparison with factory-obtained values by manufacturers. In the realm of engineering failure analysis, these values can be utilised to evaluate the mechanical failures of paper-based materials utilised as structural components in power transformers.es_ES
dc.description.sponsorshipThe authors gratefully acknowledge funding for this work from the Ministerio de Ciencia e Innovación , under the grant agreement PID2019-107126RB-C22.es_ES
dc.format.extent9 p.es_ES
dc.language.isoenges_ES
dc.publisherElsevier BVes_ES
dc.rightsAttribution 4.0 Internationales_ES
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.sourceData in Brief, 2023, 50, 109471 - (CORRIGENDUM), 2023, 50, 109498es_ES
dc.subject.otherCellulosic insulation of power transformerses_ES
dc.subject.otherMechanical properties of pressboardes_ES
dc.subject.otherMechanical testing of pressboardes_ES
dc.subject.otherHigh-density pressboardes_ES
dc.subject.otherThermal ageinges_ES
dc.titleExperimental dataset on the compressive mechanical properties of high-density pressboard used in power transformers spacerses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.rights.accessRightsopenAccesses_ES
dc.identifier.DOI10.1016/j.dib.2023.109471
dc.type.versionpublishedVersiones_ES


Ficheros en el ítem

Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo

Attribution 4.0 InternationalExcepto si se señala otra cosa, la licencia del ítem se describe como Attribution 4.0 International