dc.contributor.author | Villa Benito, Enrique | |
dc.contributor.author | Arteaga Marrero, Natalia | |
dc.contributor.author | Ruiz Alzola, Juan | |
dc.date.accessioned | 2023-05-19T10:59:53Z | |
dc.date.available | 2023-05-19T10:59:53Z | |
dc.date.issued | 2020-02-26 | |
dc.identifier.issn | 1424-8220 | |
dc.identifier.uri | https://hdl.handle.net/10902/28987 | |
dc.description.abstract | Thermal imaging is a promising technology in the medical field. Recent developments in low-cost infrared (IR) sensors, compatible with smartphones, provide competitive advantages for home-monitoring applications. However, these sensors present reduced capabilities compared to more expensive high-end devices. In this work, the characterization of thermal cameras is described and carried out. This characterization includes non-uniformity (NU) effects and correction as well as the thermal cameras´ dependence on room temperature, noise-equivalent temperature difference (NETD), and response curve stability with temperature. Results show that low-cost thermal cameras offer good performance, especially when used in temperature-controlled environments, providing evidence of the suitability of such sensors for medical applications, particularly in the assessment of diabetic foot ulcers on which we focused this study. | es_ES |
dc.description.sponsorship | This research was funded by the IACTEC Technological Training program, grant number TF INNOVA 2016-2021, and by the European Union Interreg-Mac funding program, grant number MAC/1.1.b/098 (MACbioIDi project). | es_ES |
dc.format.extent | 16 p. | es_ES |
dc.language.iso | eng | es_ES |
dc.publisher | MDPI | es_ES |
dc.rights | © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license. | es_ES |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | * |
dc.source | Sensors, 2020, 20(5), 12321 | es_ES |
dc.subject.other | Thermal cameras | es_ES |
dc.subject.other | Low-cost | es_ES |
dc.subject.other | Medical applications | es_ES |
dc.subject.other | Diabetic foot | es_ES |
dc.subject.other | Microbolometer | es_ES |
dc.subject.other | NETD | es_ES |
dc.subject.other | Non-uniformity | es_ES |
dc.title | Performance assessment of low-cost thermal cameras for medical applications | es_ES |
dc.type | info:eu-repo/semantics/article | es_ES |
dc.rights.accessRights | openAccess | es_ES |
dc.identifier.DOI | 10.3390/s20051321 | |
dc.type.version | publishedVersion | es_ES |