    Implantación del listado de verificación «checklist» en la sala de hemodinámica

    Checklist implementation in catheterization laboratory

    Ver/Abrir
    ImplantacionListadoV ... (392.5Kb)
    Identificadores
    URI: https://hdl.handle.net/10902/27225
    ISSN: 1575-4146
    Compartir
    RefworksMendeleyBibtexBase
    Estadísticas
    Ver Estadísticas
    Google Scholar
    Registro completo
    Mostrar el registro completo DC
    Autoría
    Fradejas Sastre, VíctorAutoridad Unican; Alconero Camarero, Ana RosaAutoridad Unican; Veiga-Fernández, Gabriela; Alonso-Peña, Nuria; García-Martínez, Mirian
    Fecha
    2016
    Derechos
    © Asociación Española de Enfermería en Cardiología
    Publicado en
    Enfermería en cardiología Nº. 69 (3.er cuatrimestre), 2016, págs. 48-53
    Editorial
    Asociación Española de Enfermería en Cardiología
    Palabras clave
    Enfermería
    Cardiología
    Checklist
    Lista de verificación
    Seguridad del paciente
    Resumen/Abstract
    -Introducción: El Checklist (CL) ha demostrado ser una herramienta que permite resumir información, disminuir los errores y mejorar los estándares de calidad, tanto en los procedimientos quirúrgicos como en la práctica clínica. -Objetivos: evaluar el cumplimiento de un CL adaptao a una sala de hemodinámica en los pacientes sometidos a procedimientos de cardiología intervencionista. -Materiales y métodos: diseño descriptivo transversal realizado en un hospital terciario. Se incluyeron consecutivamente a 400 pacientes sometidos a un procedimiento intervencionista desde noviembre del 2014 a febrero de 2015 y se llevó a cabo utilizando un cuestionario adaptado de la Organización Mundial de la Salud. -Resultado: el 70% fueron hombres con una media inferior a las mujeres. El diagnóstico de cardiopatía isquémica fue el más frecuente (64%), con una mayor prevalencia en varones (71% vs. 29%; p<0,0001) y en trasplantados cardiacos (92% vs. 8%; p=0,02). El acceso vascular de elección fue la vía femoral (64,5%). En más de un cuarto de los CL faltaban 4 o más ítems sin rellenar. El CL se cumplimentó íntegramente en un 18,5%. - Conclusiones: el CL es un registro útil para la consecucion de los acontecimientos; permite identificar situaciones de riesgo y eventos adversos. Los ítems del CL no registrados pueden deberse a la falta de conocimientos y de motivación, por lo que es necesario implementar estrategias para mejorar el cumplimiento de las prácticas recomendadas y para la seguridad de los pacientes.
     
    -Introduction: the checklist (CL) has proven to be a tool that allows to summarize information, reduce errors and improve quality standards both in surgical procedures and in clinical practice. -Objectives: to evaluate compliance with a CL adapted to a catheterazation laboratory in patients undergoing interventional cardiology procedures. - Material and methods: cross-sectional descriptive design conducted at a tertirary care hospital. Four hundrer patients who had underwent an interventional procedure from November 2014 to February 2015 were consecutively included therein, and it was carried out with the use of an adapted questionnaire from the World Health Organization (WHO). -Results: 70% were men with a mean age lower thanh women. Ischemic heart disease was the most frequent diagnosis (64%), with a higher prevalence in males (71% vs. 29%; p<0.0001) and in heart-transplanted patients (92% vs. 8%; p=0.02). The vascular approach of choice was the femoral one (64.5%). In more than a quarter of the CLs, 4 or more items remained uncompleted. The CL was completely complied with in a 18.5%. -Conclusion: the CL is a useful recording system for the achievement of the procedures; it allows to identify risk situations and adverse events. Unrecorded CL items may be due to the lack of knowledge and motivation, whereby approaches should be implemented in order to improve the compliance with the recommended practices and for patients' safety.
    Colecciones a las que pertenece
    • D28 Artículos [236]

    UNIVERSIDAD DE CANTABRIA

    Repositorio realizado por la Biblioteca Universitaria utilizando DSpace software
    Contacto | Sugerencias
    Metadatos sujetos a:licencia de Creative Commons Reconocimiento 4.0 España
     

     

    Listar

    Todo UCreaComunidades y coleccionesFecha de publicaciónAutoresTítulosTemasEsta colecciónFecha de publicaciónAutoresTítulosTemas

    Mi cuenta

    AccederRegistrar

    Estadísticas

    Ver Estadísticas
    Sobre UCrea
    Qué es UcreaGuía de autoarchivoArchivar tesisAcceso abiertoGuía de derechos de autorPolítica institucional
    Piensa en abierto
    Piensa en abierto
    Compartir

    UNIVERSIDAD DE CANTABRIA

    Repositorio realizado por la Biblioteca Universitaria utilizando DSpace software
    Contacto | Sugerencias
    Metadatos sujetos a:licencia de Creative Commons Reconocimiento 4.0 España