    Comparison of ballistocardiogram processing methods based on fiber specklegram sensors

    Comparative of ballistocardiogram processing methods based on fiber specklegram sensors

    Ver/Abrir
    ComparativeofBallist ... (9.729Mb)
    Identificadores
    URI: https://hdl.handle.net/10902/26952
    DOI: 10.1109/JSEN.2022.3208318
    ISSN: 1530-437X
    ISSN: 1558-1748
    Compartir
    RefworksMendeleyBibtexBase
    Estadísticas
    Ver Estadísticas
    Google Scholar
    Registro completo
    Mostrar el registro completo DC
    Autoría
    Reyes González, Luis RafaelAutoridad Unican; Rodríguez Cobo, LuisAutoridad Unican; López Higuera, José MiguelAutoridad Unican
    Fecha
    2022-11-01
    Derechos
    © 2022 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.
    Publicado en
    IEEE Sensors Journal, 2022, 22(21), 20524-20530
    Editorial
    Institute of Electrical and Electronics Engineers Inc.
    Enlace a la publicación
    https://doi.org/10.1109/JSEN.2022.3208318
    Palabras clave
    Ballistocardiogram (BCG)
    Fiber-optic sensors
    Noninvasive physiologic monitoring
    Sensor data processing
    Speckle
    Resumen/Abstract
    The ballistocardiogram (BCG) is a graphic representation of the movements of the body associated with cardiac activity. In this article, a 10-min BCG has been captured for ten different volunteers with a polymer optical fiber (POF) specklegram sensor. This transducer, which is composed of a charge-coupled device (CCD) camera, a laser emitting diode, and two meters of POF, allows capturing the BCG by analyzing how the induced speckle pattern changes over time. These changes are related to cardiac activity. Several processing methods have been compared to determine which method achieves the best performance: complex cepstrum, power of spectral density (PSD), Pam-Tompkins algorithm, wavelet, autocorrelation, Savitzky?Golay filter, mean absolute deviation, and Hilbert transform. Accuracy and resource consumption have been characterized and compared for these methods. Hilbert, PSD, and Savitzky-Golay exhibit both small errors and computational costs. This article describes a baseline for the main frequency determination of POF-based BCG signals in real-time.
    Colecciones a las que pertenece
    • D50 Artículos [312]
    • D50 Proyectos de Investigación [404]
    • IDIVAL Artículos [864]
    • IDIVAL Proyectos de investigación [191]

    UNIVERSIDAD DE CANTABRIA

    Repositorio realizado por la Biblioteca Universitaria utilizando DSpace software
    Contacto | Sugerencias
    Metadatos sujetos a:licencia de Creative Commons Reconocimiento 4.0 España
     

     

    Listar

    Todo UCreaComunidades y coleccionesFecha de publicaciónAutoresTítulosTemasEsta colecciónFecha de publicaciónAutoresTítulosTemas

    Mi cuenta

    AccederRegistrar

    Estadísticas

    Ver Estadísticas
    Sobre UCrea
    Qué es UcreaGuía de autoarchivoArchivar tesisAcceso abiertoGuía de derechos de autorPolítica institucional
    Piensa en abierto
    Piensa en abierto
    Compartir

    UNIVERSIDAD DE CANTABRIA

    Repositorio realizado por la Biblioteca Universitaria utilizando DSpace software
    Contacto | Sugerencias
    Metadatos sujetos a:licencia de Creative Commons Reconocimiento 4.0 España