dc.contributor.advisor | González-Gay Mantecón, Miguel Ángel | |
dc.contributor.advisor | Blanco, Ricardo | |
dc.contributor.author | Cifrián Casuso, Pilar | |
dc.contributor.other | Universidad de Cantabria | es_ES |
dc.date.accessioned | 2022-08-23T13:12:55Z | |
dc.date.available | 2022-08-23T13:12:55Z | |
dc.date.issued | 2022-05-16 | |
dc.identifier.uri | http://hdl.handle.net/10902/25737 | |
dc.description.abstract | RESUMEN :
Introducción. La Arteritis de células gigantes es una vasculitis sistémica que
afecta a vasos de mediano y gran calibre, produciendo clínica inflamatoria e
isquémica. Hasta ahora el diagnóstico se obtenía mediante una biopsia de la
arteria temporal; sin embargo, están adquiriendo importancia otras pruebas
menos invasivas como la ecografía.
Objetivos. Evaluar la sensibilidad y especificidad de los scores calculados sobre
la ecografía Halo Count y Halo Score.
Metodología. Estudio observacional retrospectivo que incluye a 58 pacientes
con sospecha clínica de ACG sometidos a una ecografía vascular de la arteria
temporal y sus ramas y de la arteria axilar en la que se calculó el Halo Count y
el Halo Score, y sobre los que se recogieron numerosos parámetros
demográficos, clínicos y analíticos.
Resultados. La ecografía ha demostrado una alta sensibilidad (82.6%) y
especificidad (91.4%) en el diagnóstico de ACG. Así mismo el Halo Count y Halo
Score obtuvieron un área bajo la curva ROC de 0.86 y 0.80 respectivamente.
Conclusión. El sistema de medición y puntuación sobre la ecografía Halo Count
y Halo Score evidencian un alto valor diagnóstico en este estudio, aumentando
la objetividad de la valoración ecográfica. | es_ES |
dc.description.abstract | ABSTRACT :
Introduction. Giant cell arteritis is a systemic vasculitis that affects medium and
large caliber vessels, producing inflammatory and ischemic symptoms. Until now,
the diagnosis of this disease was based on performing a biopsy of the temporal
artery; however, other less invasive tests such as ultrasound are beginning to be
used.
Objectives. To evaluate the sensitivity and specificity of the scores calculated on
ultrasound Halo Count and Halo Score.
Methods. Retrospective observational study including 58 patients with clinical
suspicion of GCA who underwent vascular ultrasound of the temporal artery and
its branches and of the axillary artery in which the Halo Count and Halo Score
were calculated. In addition, many demographic, clinical and analytical
parameters were collected.
Results. Ultrasound has shown high sensitivity (82.6%) and specificity (91.4%)
in the diagnosis of GCA. Likewise, the Halo Count and Halo Score obtained an
AUC> 0.86 and 0.80 on the ROC analysis respectively.
Conclusions. The ultrasound measurement and scoring system Halo Count and
Halo Score have shown a high diagnostic value in this study, increasing the
objectivity of the ultrasound assessment. | es_ES |
dc.format.extent | 29 p. | es_ES |
dc.language.iso | spa | es_ES |
dc.rights | Atribución-NoComercial-SinDerivadas 3.0 España | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/es/ | * |
dc.subject.other | Arteritis de células gigantes | es_ES |
dc.subject.other | Ecografía | es_ES |
dc.subject.other | Signo del halo | es_ES |
dc.subject.other | Halo Count | es_ES |
dc.subject.other | Halo Score | es_ES |
dc.title | Arteritis de células gigantes, diagnóstico por ecografía | es_ES |
dc.title.alternative | Giant cell arteritis, ultrasound diagnosis | es_ES |
dc.type | info:eu-repo/semantics/bachelorThesis | es_ES |
dc.rights.accessRights | openAccess | es_ES |
dc.description.degree | Grado en Medicina | es_ES |