dc.contributor.author | López Higuera, José Miguel | |
dc.contributor.author | Rodríguez Cobo, Luis | |
dc.contributor.author | Quintela Incera, Antonio | |
dc.contributor.author | Cobo García, Adolfo | |
dc.contributor.author | Madruga Saavedra, Francisco Javier | |
dc.contributor.author | Conde Portilla, Olga María | |
dc.contributor.author | Lomer Barboza, Mauro Matías | |
dc.contributor.author | Quintela Incera, María Ángeles | |
dc.contributor.author | Mirapeix Serrano, Jesús María | |
dc.contributor.other | Universidad de Cantabria | es_ES |
dc.date.accessioned | 2013-06-27T07:07:09Z | |
dc.date.available | 2013-06-27T07:07:09Z | |
dc.date.issued | 2010-11-09 | |
dc.identifier.issn | 1996-756X | |
dc.identifier.issn | 0277-786X | |
dc.identifier.other | TEC2007-67987-CO2-01 | es_ES |
dc.identifier.other | TEC2010-20224-C02-02 | es_ES |
dc.identifier.uri | http://hdl.handle.net/10902/2528 | |
dc.description.abstract | Structural Health Monitoring (SHM) has assumed a significant role in assessing the structures safety and integrity. SHM can be understood as the integration of sensing intelligence and possibly also actuation devices to allow the structure loading and damaging conditions to be recorded, analyzed, localized and predicted in such a way that non-destructive testing becomes an integral part of the structure. SHM sensing requirements are very well suited for fiber optic sensing technology. So in this paper, after a very brief introduction of the basic SHM concepts, the main fiber optic technologies for this application will be reviewed, several examples and the main current technical challenges will be addressed and, finally, the conclusions summarized. | es_ES |
dc.description.sponsorship | The authors thank the Spanish Education and Science Ministry for funding their R&D activities through the TEC2007-67987-CO2-01 and TEC2010-20224-C02-02 projects. | es_ES |
dc.format.extent | 9 p. | es_ES |
dc.language.iso | eng | es_ES |
dc.publisher | SPIE Society of Photo-Optical Instrumentation Engineers | es_ES |
dc.rights | © 2010 Society of Photo-Optical Instrumentation Engineers. One print or electronic copy may be made for personal use only. Systematic electronic or print reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited. | es_ES |
dc.source | Proceedings of SPIE, 2010, vol. 7853, 78530D | es_ES |
dc.source | Advanced Sensor Systems and Applications IV, Pekín, 2010 | es_ES |
dc.subject.other | Optical fiber sensors | es_ES |
dc.subject.other | Fiber optics | es_ES |
dc.subject.other | Optical transducers | es_ES |
dc.subject.other | Optoelectronic units | es_ES |
dc.subject.other | Structural health building monitoring | es_ES |
dc.title | Fiber optics in structural health monitoring | es_ES |
dc.type | info:eu-repo/semantics/conferenceObject | es_ES |
dc.relation.publisherVersion | http://dx.doi.org/10.1117/12.876192 | es_ES |
dc.rights.accessRights | openAccess | es_ES |
dc.identifier.DOI | 10.1117/12.876192 | |
dc.type.version | publishedVersion | es_ES |