Mostrar el registro sencillo

dc.contributor.authorGonzález Fernández, Daniel Aquilino
dc.contributor.authorIbarra Castanedo, Clemente
dc.contributor.authorMadruga Saavedra, Francisco Javier 
dc.contributor.authorMaldague, Xavier P. V.
dc.contributor.otherUniversidad de Cantabriaes_ES
dc.date.accessioned2013-06-18T08:09:36Z
dc.date.available2013-06-18T08:09:36Z
dc.date.issued2006-04-18
dc.identifier.issn1996-756X
dc.identifier.issn0277-786X
dc.identifier.urihttp://hdl.handle.net/10902/2428
dc.description.abstractThe automatic detection of subsurface defects has become a desired goal in the application of Non Destructive Techniques. In this paper, a new algorithm based on the Radon Transform is proposed to reduce human intervention to a minimum in the field of Thermography for defect detection and/or characterization. The analysis of a thermographic sequence for the detection of subsurface defects can be reduced to the identification of the -0.5 slope in the surface temperature decay for each pixel within the image. Employing techniques commonly used in computer vision, an algorithm can be developed in order to look for the -0.5 slope in the temporal temperature decay profiles of each pixel. In our case, the Radon transform can be used to detect those -0.5 slope lines in the temporal temperature decay profiles. The final result provided by this algorithm is an image showing the different defects avoiding the necessity of evaluating parameters as relevant in other algorithms as the delayed time of the first image or any subjective point of view in the analysis. All the information is contained in only one image and leads to a quantitative estimation of the defect depths. The principal limitation is that the specimens under inspection should be semi-infinite homogeneous samples because this algorithm is supported on a 1-D Fourier diffusion equation approximation. Experimental works using a PlexiglasTM specimen were performed showing a good agreement with other semi-automated techniques.es_ES
dc.format.extent7 p.es_ES
dc.language.isoenges_ES
dc.publisherSPIE Society of Photo-Optical Instrumentation Engineerses_ES
dc.rights© 2006 Society of Photo-Optical Instrumentation Engineers. One print or electronic copy may be made for personal use only. Systematic electronic or print reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited.es_ES
dc.sourceProceedings of SPIE, 2006, vol. 6205, 62051Nes_ES
dc.sourceThermosense XXVIII, Orlando (FL), 2006es_ES
dc.subject.otherPulsed thermographyes_ES
dc.subject.otherImage processinges_ES
dc.subject.otherRadon transformes_ES
dc.subject.otherDefect detectiones_ES
dc.titleAnalysis of pulsed thermographic sequences based on radon transformes_ES
dc.typeinfo:eu-repo/semantics/conferenceObjectes_ES
dc.relation.publisherVersionhttp://dx.doi.org/10.1117/12.665461es_ES
dc.rights.accessRightsopenAccesses_ES
dc.identifier.DOI10.1117/12.665461
dc.type.versionpublishedVersiones_ES


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo