Mostrar el registro sencillo

dc.contributor.advisorPérez Álvarez, Rubén 
dc.contributor.authorFernández Pereda, Álvaro
dc.contributor.otherUniversidad de Cantabriaes_ES
dc.date.accessioned2021-07-14T09:52:24Z
dc.date.available2021-07-14T09:52:24Z
dc.date.issued2021-06
dc.identifier.urihttp://hdl.handle.net/10902/21986
dc.description.abstractRESUMEN: La demolición de una estructura consiste en la destrucción y el derribo de la misma, pudiendo distinguirse entre demoliciones parciales, las cuáles solo pretenden conseguir el derribo de una parte concreta, o demoliciones totales, que tienen por objeto la caída total de la estructura. Para ello existen diferentes métodos de demolición, como pueden ser los medios manuales, los medios mecánicos (uso de maquinaria) o el uso de explosivos, pudiendo realizarse una combinación de ellos. El derrumbe de un edificio viene marcado por las características constructivas del mismo, es por ello que factores como el peso de la estructura, la altura o la esbeltez definen el método de demolición a seguir. El presente trabajo consiste en el diseño de una voladura para demoler un edificio de viviendas ubicado en la ciudad de Santander. La superficie que se pretende despejar con el derribo de la estructura es de 2510,00 m2 , coincidiendo esta cifra con la de ocupación del edificio, el cual presenta una forma trapezoidal con las esquinas en chaflán y a modo de manzana cerrada con sus cuatro fachadas a viario público. Para conseguir una demolición efectiva se debe actuar sobre los elementos portantes de la estructura, como son pilares de hormigón armado de dimensiones variables (20x60 cm, 20x80 cm, 30x30 cm, 30x35 cm, 30x40 cm, 35x35 cm, 35x40 cm, 35x 45 cm, 35x50 cm, 40x40 cm, 45x45 cm), losas de hormigón armado de espesor 24 y 29 cm, escaleras de 15 cm de canto y muros de ascensores de 20 cm de grosor. Sabiendo la distancia al edificio más cercano, 85m, se aplica el estudio de onda aérea, el cual estipula la máxima carga por microrretardo que se puede disparar, 30,88Kg. Por último, se realiza el diseño de la secuenciación en función de la dirección de caída que se desea conseguir. En el presente edificio se ha optado por realizar la voladura de las plantas -2, -1, 0, 1 y 2, de tal manera que las dos plantas sótano sirvan de hueco para recoger la gran parte de material volado, realizándose una secuenciación de abajo hacia arriba, con la peculiaridad de que se explotaran primero los pilares más céntricos de cada planta avanzando en la secuencia hacia los pilares más perimetrales.es_ES
dc.description.abstractABSTRACT: The demolition of a structure consists of the destruction and demolition of the same, it being possible to distinguish between partial demolitions, which only aim to achieve the demolition of a specific part, or total demolitions, which are aimed at the total fall of the structure. For this, there are different demolition methods, such as manual means, mechanical means (use of machinery) or the use of explosives, and a combination of them can be carried out. The collapse of a building is determined by its constructive characteristics, which is why factors such as the weight of the structure, height or slenderness define the demolition method to be followed. The present work consists of the design of a blast to demolish a residential building located in the city of Santander. The area to be cleared with the demolition of the structure is 2510.00 m2, this figure coinciding with the occupation of the building, which has a trapezoidal shape with chamfered corners and as a closed block with its four facades at public road. To achieve an effective demolition, the load-bearing elements of the structure must be acted upon, such as reinforced concrete pillars of variable dimensions (20x60 cm, 20x80 cm, 30x30 cm, 30x35 cm, 30x40 cm, 35x35 cm, 35x40 cm, 35x 45 cm , 35x50 cm, 40x40 cm, 45x45 cm), 24 and 29 cm thick reinforced concrete slabs, 15 cm deep stairs and 20 cm thick elevator walls. Knowing the distance to the closest building, 85m, the air wave study is applied, which stipulates the maximum load per micro-delay that can be shot, 30.88Kg. Finally, the design of the sequencing is carried out according to the direction of fall that is desired to be achieved. In the present building, it has been chosen to blast floors -2, -1, 0, 1 and 2, in such a way that the two basement floors serve as a hole to collect the large part of blown material, performing a sequencing of bottom up, with the peculiarity that the most central pillars of each floor were exploited first, advancing in the sequence towards the most perimeter pillars.es_ES
dc.format.extent219 páginases_ES
dc.language.isospaes_ES
dc.rights©Álvaro Fernández Peredaes_ES
dc.subject.otherDemoliciónes_ES
dc.subject.otherVoladuraes_ES
dc.subject.otherExplosivoses_ES
dc.subject.otherCarga operantees_ES
dc.subject.otherSecuenciaciónes_ES
dc.subject.otherDemolitiones_ES
dc.subject.otherBlastinges_ES
dc.subject.otherExplosiveses_ES
dc.subject.otherOperating loades_ES
dc.subject.otherSequencinges_ES
dc.titleDiseño de una voladura para la demolición de un edificioes_ES
dc.title.alternativeBlasting design for a bulding demolitiones_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
dc.rights.accessRightsrestrictedAccesses_ES
dc.description.degreeGrado en Ingeniería de los Recursos Mineroses_ES


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo