dc.contributor.author | Fuente Rodríguez, Luisa María de la | |
dc.contributor.author | Aja Abelán, Beatriz | |
dc.contributor.author | Villa Benito, Enrique | |
dc.contributor.author | Artal Latorre, Eduardo | |
dc.contributor.other | Universidad de Cantabria | es_ES |
dc.date.accessioned | 2021-06-23T08:43:20Z | |
dc.date.available | 2021-06-23T08:43:20Z | |
dc.date.issued | 2021-05 | |
dc.identifier.issn | 2072-4292 | |
dc.identifier.other | ESP2015-70646-C2-2-R | es_ES |
dc.identifier.other | ESP2017-83921-C2-2-R | es_ES |
dc.identifier.other | PID2019-110610RB-C22 | es_ES |
dc.identifier.uri | http://hdl.handle.net/10902/21915 | |
dc.description.abstract | This paper presents a built-in calibration procedure of a 10-to-20 GHz polarimeter aimed at measuring the I, Q, U Stokes parameters of cosmic microwave background (CMB) radiation. A full-band square waveguide double directional coupler, mounted in the antenna-feed system, is used to inject differently polarized reference waves. A brief description of the polarimetric microwave radiometer and the system calibration injector is also reported. A fully polarimetric calibration is also possible using the designed double directional coupler, although the presented calibration method in this paper is proposed to obtain three of the four Stokes parameters with the introduced microwave receiver, since V parameter is expected to be zero for the CMB radiation. Experimental results are presented for linearly polarized input waves in order to validate the built-in calibration system. | es_ES |
dc.description.sponsorship | The authors would like to thank The Spanish Ministry of Science and Innovation for financial support provided through the grants ESP2015-70646-C2-2-R, ESP2017-83921-C2-2-R and PID2019-110610RB-C22 | es_ES |
dc.format.extent | 17 p. | es_ES |
dc.language.iso | eng | es_ES |
dc.publisher | MDPI | es_ES |
dc.rights | © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license. | es_ES |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | * |
dc.source | Remote Sensing, 2021, 13(11), 2109 | es_ES |
dc.subject.other | Radiometer | es_ES |
dc.subject.other | Polarimeter calibration | es_ES |
dc.subject.other | Microwave polarimeter | es_ES |
dc.subject.other | Radiometer calibration | es_ES |
dc.subject.other | Radio astronomy receiver | es_ES |
dc.subject.other | Cosmic microwave background receiver | es_ES |
dc.subject.other | Stokes parameters | es_ES |
dc.title | Calibration of a polarimetric microwave radiometer using a double directional coupler | es_ES |
dc.type | info:eu-repo/semantics/article | es_ES |
dc.rights.accessRights | openAccess | es_ES |
dc.identifier.DOI | 10.3390/rs13112109 | |
dc.type.version | publishedVersion | es_ES |