dc.description.abstractThe anti-HLA antibody detection has been improved in sensitivity and specificity with solid-phase antigen bead (SAB) assays based on Luminex. However, false positive results due to denatured HLA (dHLA) may arise after single antigen test. The aim of this study was to compare the performance of the two Luminex technology-based anti-HLA detection kits available in the market in showing undesired anti-HLA antibody results. A prospective cohort was assessed for anti-HLA antibodies with single antigen A manufacturer (AM) kit and a comparison cohort with single antigen B manufacturer (BM) kit. A total of 11 out of 90 patients in a prospective cohort presented monospecific HLA-I antibodies with AM, and 5 out of 11 confirmed monospecific reaction with BM. Despite the confirmation of monospecific reaction with both manufacturers, 80% were assigned as dHLA reaction by specific crossmatch. Further comparative cohorts detected four out of six monospecific reactions with BM that were confirmed as possible dHLA reactions. A positive SAB test should rule out a reaction against a dHLA molecule, thus avoidance of prolonged waitlist periods or misattribution of anti-HLA reactions after transplantation.es_ES
dc.format.extent8 p.es_ES
dc.language.isoenges_ES
dc.publisherWiley Blackwelles_ES
dc.rightshis is the pre-peer reviewed version of the following article: [Gutiérrez-Larrañaga M,Riesco L, Guiral S, et al. Detection of antibodies todenatured human leucocyte antigen molecules bysingle antigen Luminex. HLA. 2021;97:52?59.https://doi.org/10.1111/tan.1 4098], which has been published in final form at [https://onlinelibrary.wiley.com/doi/epdf/10.1111/tan.14098]. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versionses_ES
dc.sourceHLA. 2021;97(1):52-59es_ES
dc.subject.otherHLA antigenses_ES
dc.subject.otherImmunologyes_ES
dc.subject.otherAntibodieses_ES
dc.subject.otherFlow cytometryes_ES
dc.subject.otherMicrosphereses_ES
dc.subject.otherCytotoxicity Testses_ES
dc.subject.otherHistocompatibility testinges_ES
dc.titleDetection of antibodies to denatured human leucocyte antigen molecules by single antigen Luminexes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.relation.publisherVersionhttps://onlinelibrary.wiley.com/doi/epdf/10.1111/tan.14098es_ES
dc.rights.accessRightsopenAccesses_ES
dc.identifier.DOI10.1111/tan.14098
dc.type.versionacceptedVersiones_ES


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo