    Performance analysis of natural, synthetic and mineral oil in a 100 MVA power transformer

    Ver/Abrir
    PerformanceAnalysiso ... (998.0Kb)
    Identificadores
    URI: http://hdl.handle.net/10902/21725
    DOI: 10.1109/ICD46958.2020.9341919
    ISBN: 978-1-7281-8983-3
    Compartir
    RefworksMendeleyBibtexBase
    Estadísticas
    Ver Estadísticas
    Google Scholar
    Registro completo
    Mostrar el registro completo DC
    Autoría
    Altay, Ramazan; Santisteban Díaz, AgustínAutoridad Unican; Olmo Salas, CristianAutoridad Unican; Delgado San Román, FernandoAutoridad Unican; Renedo Estébanez, Carlos J.Autoridad Unican; Köseoglu, A. Kerem; Ortiz Fernández, AlfredoAutoridad Unican
    Fecha
    2020
    Derechos
    © 2020 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works
    Publicado en
    3rd IEEE International Conference on Dielectrics (ICD), Valencia, 2020, 770-773
    Enlace a la publicación
    https://doi.org/10.1109/ICD46958.2020.9341919
    Resumen/Abstract
    The power transformer lifespan depends on the dielectric capacity of its insulation system, mainly of the paper. Integrity of this material depends significantly on the cooling capacity of the oil used to cool it. Currently, ester-based fluids are being researched with the intention to substitute the traditional cooling liquid in power transformers, the mineral oil. Here, cooling capacity of two different ester-based fluids, a synthetic and anatural esters, is compared with that of a mineral oil. To carry out this task, CFD results of a low voltage winding of a 100 MVA power transformer jointly with the experimental ones get from a heat-run test done in this transformer are used. This winding has an axial cooling system in ON regime. As a result of this study, it can be inferred that alternative liquids could be used with high load levels (rated power or higher) since no significant changes in the temperatures distribution of the winding cooled with these fluids in comparison with that get with mineral oil are appreciated.
    Colecciones a las que pertenece
    • D19 Congresos [94]
    • D19 Proyectos de investigación [103]

    UNIVERSIDAD DE CANTABRIA

    Repositorio realizado por la Biblioteca Universitaria utilizando DSpace software
    Contacto | Sugerencias
    Metadatos sujetos a:licencia de Creative Commons Reconocimiento 4.0 España
     

     

    Listar

    Todo UCreaComunidades y coleccionesFecha de publicaciónAutoresTítulosTemasEsta colecciónFecha de publicaciónAutoresTítulosTemas

    Mi cuenta

    AccederRegistrar

    Estadísticas

    Ver Estadísticas
    Sobre UCrea
    Qué es UcreaGuía de autoarchivoArchivar tesisAcceso abiertoGuía de derechos de autorPolítica institucional
    Piensa en abierto
    Piensa en abierto
    Compartir

    UNIVERSIDAD DE CANTABRIA

    Repositorio realizado por la Biblioteca Universitaria utilizando DSpace software
    Contacto | Sugerencias
    Metadatos sujetos a:licencia de Creative Commons Reconocimiento 4.0 España