dc.description.abstractIn order to make an equitable application of bonuses or extra charges due to harmonic distortion, it is necessary to separate between harmonics exported by nonlinear loads used by costumers, and imported ones due to distortion at Point of Common Coupling (PCC) property of the electric utility. On this paper, a new methodology is presented to assign each costumer his own distortion. Same sampling instrumentation applied in charging electrical bills -with new software- registers total exported harmonic current, making possible determination of corrected non-sinusoidal apparent power and equivalent power factor during an invoicing period. Some effects of nonlinear loads on grids are determined and analyzed, and experiments done on compact fluorescent lamps are shown and described.es_ES
dc.description.sponsorshipThe authors gratefully acknowledge the financial support of the Ministry of Science and Technology of Spain through the Project no. CTM2006-00317es_ES
dc.format.extent6 p.es_ES
dc.language.isoenges_ES
dc.publisherEuropean Association for the Development of Renewable Energies, Environment and Power Quality (EA4EPQ)es_ES
dc.rights© The European Association for the Development of Renewable Energies, Environment and Power Quality (EA4EPQ)es_ES
dc.sourceRenewable Energy and Power Quality Journal (RE&PQJ), 2008, 1(6), 813-818es_ES
dc.sourceInternational Conference on Renewable Energies and Power Quality (ICREPQ’08), Santanderes_ES
dc.subject.otherAdjusted equivalent power factores_ES
dc.subject.otherAdjusted equivalent apparent poweres_ES
dc.subject.otherExported harmonic currentes_ES
dc.subject.otherSampling instrumentationes_ES
dc.subject.otherNonlinear loades_ES
dc.titleMethodology for harmonic distortion level determinationes_ES