High-Frequency Fatigue Testing of Recycled Aggregate Concrete
Ver/ Abrir
Registro completo
Mostrar el registro completo DCAutoría
Sainz-Aja Guerra, José Adolfo



Fecha
2020-01Derechos
© 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution 4.0 (CC BY) license.
Publicado en
Applied Sciences 2020, 10(1) 10
Editorial
MDPI
Resumen/Abstract
ABSTRACT: Concrete fatigue behaviour has not been extensively studied, in part because of the difficulty and cost. Some concrete elements subjected to this type of load include the railway superstructure of sleepers or slab track, bridges for both road and rail traffic and the foundations of wind turbine towers or offshore structures. In order to address fatigue problems, a methodology was proposed that reduces the lengthy testing time and high cost by increasing the test frequency up to the resonance frequency of the set formed by the specimen and the test machine. After comparing this test method with conventional frequency tests, it was found that tests performed at a high frequency (90 ± 5 Hz) were more conservative than those performed at a moderate frequency (10 Hz); this effect was magnified in those concretes with recycled aggregates coming from crushed concrete (RC-S). In addition, it was found that the resonance frequency of the specimen?test machine set was a parameter capable of identifying whether the specimen was close to failure.