• Mi UCrea
    Ver ítem 
    •   UCrea
    • UCrea Investigación
    • Departamento de Física Moderna
    • D15 Artículos
    • Ver ítem
    •   UCrea
    • UCrea Investigación
    • Departamento de Física Moderna
    • D15 Artículos
    • Ver ítem
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Measurement of the B- lifetime using a simulation free approach for trigger bias correction

    Ver/Abrir
    Measurement of the ... (1.426Mb)
    Identificadores
    URI: http://hdl.handle.net/10902/1874
    DOI: 10.1103/PhysRevD.83.032008
    ISSN: 1550-7998
    ISSN: 1550-2368
    Compartir
    RefworksMendeleyBibtexBase
    Estadísticas
    Ver Estadísticas
    Google Scholar
    Registro completo
    Mostrar el registro completo DC
    Autoría
    Aaltonen, Timo Antero; Adelman, Jahred; Álvarez González, Bárbara; Amerio, Silvia; Amidei, Dante; Anastassov, Anton; Annovi, Alberto; Antos, Jaroslav; Apollinari, Giorgio; Appel, Jeffrey A.; Apresyan, Artur; Casal Laraña, Bruno; Cuevas Maestro, Francisco Javier; Gómez Gramuglio, GervasioAutoridad Unican; Rodrigo Anoro, TeresaAutoridad Unican; Ruiz Jimeno, AlbertoAutoridad Unican; Scodellaro, LucaAutoridad Unican; Vila Álvarez, Iván Autoridad Unican; Vilar Cortabitarte, RocíoAutoridad Unican; [et al.]
    Fecha
    2011-02-16
    Derechos
    © 2011 American Physical Society
    Publicado en
    Physical Review D. Particles, fields, gravitation, and cosmology, vol 83, iss. 3, art. num. 032008 (2011)
    Editorial
    American Physical Society
    Enlace a la publicación
    http://dx.doi.org/10.1103/PhysRevD.83.032008
    Resumen/Abstract
    The collection of a large number of B-hadron decays to hadronic final states at the CDF II Detector is possible due to the presence of a trigger that selects events based on track impact parameters. However, the nature of the selection requirements of the trigger introduces a large bias in the observed proper-decay-time distribution. A lifetime measurement must correct for this bias, and the conventional approach has been to use a Monte Carlo simulation. The leading sources of systematic uncertainty in the conventional approach are due to differences between the data and the Monte Carlo simulation. In this paper, we present an analytic method for bias correction without using simulation, thereby removing any uncertainty due to the differences between data and simulation. This method is presented in the form of a measurement of the lifetime of the B- using the mode B-→D0π-. The B- lifetime is measured as τB-=1.663±0.023±0.015 ps, where the first uncertainty is statistical and the second systematic. This new method results in a smaller systematic uncertainty in comparison to methods that use simulation to correct for the trigger bias.
    Colecciones a las que pertenece
    • D15 Artículos [846]
    • D52 Artículos [1337]

    UNIVERSIDAD DE CANTABRIA

    Repositorio realizado por la Biblioteca Universitaria utilizando DSpace software
    Contacto | Sugerencias
    Metadatos sujetos a:licencia de Creative Commons Reconocimiento 4.0 España
     

     

    Listar

    Todo UCreaComunidades y coleccionesFecha de publicaciónAutoresTítulosTemasEsta colecciónFecha de publicaciónAutoresTítulosTemas

    Mi cuenta

    AccederRegistrar

    Estadísticas

    Ver Estadísticas
    Sobre UCrea
    Qué es UcreaGuía de autoarchivoArchivar tesisAcceso abiertoGuía de derechos de autorPolítica institucional
    Piensa en abierto
    Piensa en abierto
    Compartir

    UNIVERSIDAD DE CANTABRIA

    Repositorio realizado por la Biblioteca Universitaria utilizando DSpace software
    Contacto | Sugerencias
    Metadatos sujetos a:licencia de Creative Commons Reconocimiento 4.0 España