dc.description.abstractRESUMEN: El objetivo principal del trabajo fue la optimización de las técnicas de las diferentes vistas radiográficas de un equipo de radiografía digital, de la marca Carestream, modelo DRX Evolution Plus, situado en el Servicio de Radiología del Hospital de Sierrallana. La optimización ha consistido en el cálculo de la carga (mAs) necesaria para obtener un kerma en aire incidente sobre el receptor de imagen predefinido. Esto ha permitido definir técnicas manuales y ajustar la carga de seguridad de aquellas técnicas realizadas con el Control Automático de Exposición (CAE). Para ello se ha desarrollado un modelo de cálculo que tiene en cuenta las características particulares de la sala bajo estudio y del paciente. Se ha considerado el rendimiento y la filtración total del tubo, el tamaño del paciente (pequeño, mediano y grande), la atenuación del tablero y de las cámaras del CAE, y la selectividad de los métodos de rechazo de la radiación dispersa (rejilla antidifusora y espaciado entre el plano de salida del paciente y el receptor de imagen). El modelo puede calcular el kerma en aire por unidad de carga en cualquier punto de la cadena de imagen y, por tanto, la carga para obtener un kerma en aire de 2.5 µGy en el receptor. El modelo se ha verificado experimentalmente en distintas condiciones y se ha aplicado posterior- mente al cálculo de las técnicas de las vistas radiográficas.es_ES
dc.description.abstractABSTRACT: The main objective of the project was the optimization of the views and radiographic techniques of a digital radiography equipment, the Carestream DRX Evolution Plus, located at Radiology Department of the Sierrallana Hospital. The optimization has consisted in the calculation of the charge (mAs) necessary to obtain a kerma in air predefined on the image receptor, which has made the definition of manual techniques possible, as well as the adjustment of the safety charge of those techniques performed with Automatic Exposure Control (AEC). For this purpose, a calculation model, which takes into account the particular characteristics of the room under study and of the patient, has been developed. The following parameters have been considered in the aforementioned model: the eficiency and total filtration of the tube, the size of the patient (Small, medium and large), the attenuation of the patient support and the AEC chambers, and the selectivity of scatter radiation rejection methods (i.e antiscatter grids and spacing between the exit surface of the patient and the image receptor). The model can compute the kerma in air per unit of charge at any point of the image chain and, therefore, the charge needed to obtain a kerma in air of 2.5 μGy on the image receptor. This model has been experimentally validated by means of the performance of different tests carried out under distinct conditions, and it has been subsequently applied to the calculation of the techniques of the radiographic views.es_ES
dc.format.extent68es_ES
dc.language.isospaes_ES
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 España*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/*
dc.subject.otherOptimización de técnicas radiográficases_ES
dc.subject.otherKerma en receptores_ES
dc.subject.otherAjuste del CAEes_ES
dc.subject.otherSelectividad de los métodos de rechazo de radiación dispersaes_ES
dc.subject.otherRadiodiagnósticoes_ES
dc.subject.otherOptimization of radiographic techniqueses_ES
dc.subject.otherKerma in image receptores_ES
dc.subject.otherAEC adjustmentes_ES
dc.subject.otherSelectivity of scatter radiation rejection methodses_ES
dc.subject.otherRadiodiagnosises_ES
dc.titleOptimización de las técnicas radiográficas de un equipo de radiografía digital Carestream DRX Evolutiones_ES
dc.title.alternativeOptimization of radiographic techniques of the Carestream DRX Evolution digital radiography equipmentes_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES