• Mi UCrea
    Ver ítem 
    •   UCrea
    • UCrea Investigación
    • Instituto de Física de Cantabria (IFCA) - centro mixto UC-CSIC
    • D52 Artículos
    • Ver ítem
    •   UCrea
    • UCrea Investigación
    • Instituto de Física de Cantabria (IFCA) - centro mixto UC-CSIC
    • D52 Artículos
    • Ver ítem
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Planck 2013 results. VI. High Frequency Instrument data processing

    Ver/Abrir
    aa21570 13.pdf (32.67Mb)
    Identificadores
    URI: http://hdl.handle.net/10902/13832
    DOI: 10.1051/0004-6361/201321570
    ISSN: 0004-6361
    ISSN: 1432-0746
    Compartir
    RefworksMendeleyBibtexBase
    Estadísticas
    Ver Estadísticas
    Google Scholar
    Registro completo
    Mostrar el registro completo DC
    Autoría
    Ade, Peter Anthony Robert; Barreiro Vilas, Rita BelénAutoridad Unican; Curto Martín, Andrés; Diego Rodríguez, José MaríaAutoridad Unican; González-Nuevo González, Joaquín; Herranz Muñoz, DiegoAutoridad Unican; López-Caniego Alcarria, Marcos; Martínez González, Enrique; Vielva Martínez, PatricioAutoridad Unican
    Fecha
    2014-11
    Derechos
    © ESO, 2014
    Publicado en
    A&A 571, A6 (2014)
    Editorial
    EDP Sciences
    Enlace a la publicación
    https://doi.org/10.1051/0004-6361/201321570
    Resumen/Abstract
    We describe the processing of the 531 billion raw data samples from the High Frequency Instrument (HFI), which we performed to produce six temperature maps from the first 473 days of Planck-HFI survey data. These maps provide an accurate rendition of the sky emission at 100, 143, 217, 353, 545, and 857GHz with an angular resolution ranging from 9.´7 to 4.´6. The detector noise per (effective) beam solid angle is respectively, 10, 6 , 12, and 39?µK in the four lowest HFI frequency channels (100-353GHz) and 13 and 14?kJy sr-1 in the 545 and 857?GHz channels. Relative to the 143?GHz channel, these two high frequency channels are calibrated to within 5% and the 353?GHz channel to the percent level. The 100 and 217?GHz channels, which together with the 143?GHz channel determine the high-multipole part of the CMB power spectrum (50 <l < 2500), are calibrated relative to 143?GHz to better than 0.2%.
    Colecciones a las que pertenece
    • D52 Artículos [1340]

    UNIVERSIDAD DE CANTABRIA

    Repositorio realizado por la Biblioteca Universitaria utilizando DSpace software
    Contacto | Sugerencias
    Metadatos sujetos a:licencia de Creative Commons Reconocimiento 4.0 España
     

     

    Listar

    Todo UCreaComunidades y coleccionesFecha de publicaciónAutoresTítulosTemasEsta colecciónFecha de publicaciónAutoresTítulosTemas

    Mi cuenta

    AccederRegistrar

    Estadísticas

    Ver Estadísticas
    Sobre UCrea
    Qué es UcreaGuía de autoarchivoArchivar tesisAcceso abiertoGuía de derechos de autorPolítica institucional
    Piensa en abierto
    Piensa en abierto
    Compartir

    UNIVERSIDAD DE CANTABRIA

    Repositorio realizado por la Biblioteca Universitaria utilizando DSpace software
    Contacto | Sugerencias
    Metadatos sujetos a:licencia de Creative Commons Reconocimiento 4.0 España