© 2016 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works."
Publicado en
IEEE Transactions on Power Delivery 31(1), 2016, pp 262-270
Editorial
Institute of Electrical and Electronics Engineers Inc.
Enlace a la publicación
Resumen/Abstract
A rapid voltage change (RVC) is a type of power-quality (PQ) disturbance that has not received sufficient attention in the international PQ standards. Presently, EC 61000-4-30, Ed. 3, defines a precise method for RVC detection and analysis. RVCs can cause or contribute to flicker. However, the existing studies on the subject have not found a correlation between the short-term flicker severity index Pst and the parameters of an RVC event. This paper provides an interpretation of this lack of correlation and shows that instead there is a correlation of RVC events with the instantaneous flicker sensation Pinst. This work is based on the analysis of both simulated waveforms containing RVCs and waveforms recorded in low-voltage and medium-voltage locations.