Mostrar el registro sencillo

dc.contributor.authorMolina, Davides_ES
dc.contributor.authorPérez Beteta, Juliánes_ES
dc.contributor.authorMartínez González, Aliciaes_ES
dc.contributor.authorMartino González, Juan es_ES
dc.contributor.authorVelasquez, Carloses_ES
dc.contributor.authorArana, Estanislaoes_ES
dc.contributor.authorPérez García, Víctor M.es_ES
dc.contributor.otherUniversidad de Cantabriaes_ES
dc.date.accessioned2017-10-09T17:07:12Z
dc.date.available2017-10-09T17:07:12Z
dc.date.issued2017es_ES
dc.identifier.issn1932-6203es_ES
dc.identifier.urihttp://hdl.handle.net/10902/12086
dc.description.abstractPurpose Textural measures have been widely explored as imaging biomarkers in cancer. However, their robustness under dynamic range and spatial resolution changes in brain 3D magnetic resonance images (MRI) has not been assessed. The aim of this work was to study potential variations of textural measures due to changes in MRI protocols. Materials and methods Twenty patients harboring glioblastoma with pretreatment 3D T1-weighted MRIs were included in the study. Four different spatial resolution combinations and three dynamic ranges were studied for each patient. Sixteen three-dimensional textural heterogeneity measures were computed for each patient and configuration including co-occurrence matrices (CM) features and run-length matrices (RLM) features. The coefficient of variation was used to assess the robustness of the measures in two series of experiments corresponding to (i) changing the dynamic range and (ii) changing the matrix size. Results No textural measures were robust under dynamic range changes. Entropy was the only textural feature robust under spatial resolution changes (coefficient of variation under 10% in all cases). Conclusion Textural measures of three-dimensional brain tumor images are not robust neither under dynamic range nor under matrix size changes. Standards should be harmonized to use textural features as imaging biomarkers in radiomic-based studies. The implications of this work go beyond the specific tumor type studied here and pose the need for standardization in textural feature calculation of oncological images.es_ES
dc.format.extent14 p.es_ES
dc.language.isoenges_ES
dc.publisherPublic Library of Sciencees_ES
dc.rightsAtribución 3.0 España*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.sourcePLoS ONE 12(6): e0178843es_ES
dc.titleLack of robustness of textural measures obtained from 3D brain tumor MRIs impose a need for standardizationes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.rights.accessRightsopenAccesses_ES
dc.identifier.DOI10.1371/journal.pone.0178843es_ES
dc.type.versionpublishedVersiones_ES


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo

Atribución 3.0 EspañaExcepto si se señala otra cosa, la licencia del ítem se describe como Atribución 3.0 España