dc.contributor.author | Álvarez Guerra, Enrique | |
dc.contributor.author | Ventura, Sónia Patrícia Marques | |
dc.contributor.author | Álvarez Guerra, Manuel | |
dc.contributor.author | Coutinho, João A. P. | |
dc.contributor.author | Irabien Gulías, Ángel | |
dc.contributor.other | Universidad de Cantabria | es_ES |
dc.date.accessioned | 2017-06-08T15:17:06Z | |
dc.date.available | 2017-10-31T03:45:09Z | |
dc.date.issued | 2016-10-25 | |
dc.identifier.issn | 0378-3812 | |
dc.identifier.issn | 1879-0224 | |
dc.identifier.uri | http://hdl.handle.net/10902/11179 | |
dc.description.abstract | Ionic Liquid-based Aqueous Two Phase Systems (ILATPS) are an innovative technique to separate biomolecules that combines the advantages of liquid–liquid extraction and hydrophilic ionic liquids. Most ILATPS are based on ionic liquids and conventional inorganic salts, and the phase envelope, described by the binodal curve, is usually modeled by empirical equations that are used to determine the phase compositions and assess the ionic liquid recyclability. However, these empirical equations may provide a poor extrapolation ability or low accuracy at the extreme regions of the binodal curve or suffer from problems of convergence. Therefore, the aim of this work is the analysis of the binodal curve equations, comparing the models reported in the literature to describe ILATPS and proposing alternative equations to improve accuracy or to reduce the mathematical complexity. For this purpose, a database compiling binodal experimental data of 100 ILATPS has been built, so that the analysis could make it possible to obtain representative conclusions for all these systems. Several models were developed, and different statistical criteria were used to assess the advantages and disadvantages of each one of these models for the binodal curve. The results show that, when accuracy is critical, a proposed model with just an additional parameter reduced more than 25% the residual mean squared error (RMSE) with respect to the commonly used equation, without losing the statistical significance of the parameters. For complex problems where an explicit equation in both the concentration of ionic liquid and of salt is needed, the use of an explicit model developed with 3 adjusted parameters that kept high accuracy (R2 > 0.996 and RMSE < 0.66) is proposed. Finally, the analysis also revealed that a fitting method based on the minimization of relative errors is recommended to increase the accuracy of the binodal curve at high salt concentrations, which is the crucial region for assessing the recyclability of the ionic liquid. | es_ES |
dc.description.sponsorship | This work was developed in the scope of the project CICECO Aveiro Institute of Materials (Ref. FCT UID/CTM/50011/2013), financed by national funds through the FCT/MEC and co-financed by FEDER under the PT2020 Partnership Agreement. The authors also acknowledge FCT for the Post-doctoral grant SFRH/BPD/79263/2011 of S.P.M. Ventura. | es_ES |
dc.format.extent | 23 p. | es_ES |
dc.language.iso | eng | es_ES |
dc.publisher | Elsevier | es_ES |
dc.rights | © 2016, Elsevier. Licensed under the Creative Commons Reconocimiento-NoComercial-SinObra-Derivada | es_ES |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/es/ | * |
dc.source | Fluid Phase Equilibria, 2016, 426, 10-16 | es_ES |
dc.subject.other | Aqueous biphasic system | es_ES |
dc.subject.other | Binodal curve | es_ES |
dc.subject.other | Model | es_ES |
dc.subject.other | Accuracy | es_ES |
dc.subject.other | Ionic liquid recyclability | es_ES |
dc.title | Modeling of the binodal curve of ionic liquid/salt aqueous systems | es_ES |
dc.type | info:eu-repo/semantics/article | es_ES |
dc.relation.publisherVersion | https://doi.org/10.1016/j.fluid.2016.01.004 | es_ES |
dc.rights.accessRights | openAccess | es_ES |
dc.identifier.DOI | 10.1016/j.fluid.2016.01.004 | |
dc.type.version | acceptedVersion | es_ES |