• Mi UCrea
    Ver ítem 
    •   UCrea
    • UCrea Investigación
    • Departamento de Ingeniería Eléctrica y Energética (DIEE)
    • D19 Proyectos de investigación
    • Ver ítem
    •   UCrea
    • UCrea Investigación
    • Departamento de Ingeniería Eléctrica y Energética (DIEE)
    • D19 Proyectos de investigación
    • Ver ítem
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Differences using measured and calculated solar radiation in order to estimate the temperature of the conductor in overhead lines

    Ver/Abrir
    DifferencesUsingMeas ... (1.051Mb)
    Identificadores
    URI: http://hdl.handle.net/10902/10983
    DOI: 10.24084/repqj/14.452
    ISSN: 2172-038X
    Compartir
    RefworksMendeleyBibtexBase
    Estadísticas
    Ver Estadísticas
    Google Scholar
    Registro completo
    Mostrar el registro completo DC
    Autoría
    Domingo Fernández, RodrigoAutoridad Unican; González Diego, AntonioAutoridad Unican; Mañana Canteli, MarioAutoridad Unican; Arroyo Gutiérrez, AlbertoAutoridad Unican; Cavia Soto, María de los ÁngelesAutoridad Unican; Olmo de Celis, Cesar Juan del
    Fecha
    2016-05
    Derechos
    © The European Association for the Development of Renewable Energies, Environment and Power Quality (EA4EPQ)
    Publicado en
    Renewable Energy & Power Quality Journal (RE&PQJ), 2016, 1(14), 780-784
    International Conference on Renewable Energies and Power Quality (ICREPQ'16), Madrid
    Editorial
    The European Association for the Development of Renewable Energies, Environment and Power Quality (EA4EPQ)
    Palabras clave
    Conductor temperature
    Ampacity
    Solar radiation
    Pyranometer
    Resumen/Abstract
    In the last 20 years, installed wind power capacity in North of Spain has grown from 24 to more than 1,650 MW. In this geographical region, wind energy farms are located in places that are far away from the transmission networks so they have to be integrated into distribution networks. Build new overhead lines dedicated for a distribution energy is not the best way to increase the evacuation energy of the wind farms because the cost is quite strong. So, the aim to solve these issues, is by means of an increase in the capacity of existing lines using the dynamic management of the network. This paper is devoted to show the difference of the conductor temperature between the parameter of solar radiation measured by a pyranometer and the use of the theoretical solar radiation which is explained in CIGRE TB601 [1] and IEEE Std. 738-2012 [2] algorithms.
    Colecciones a las que pertenece
    • D19 Congresos [94]
    • D19 Proyectos de investigación [102]

    UNIVERSIDAD DE CANTABRIA

    Repositorio realizado por la Biblioteca Universitaria utilizando DSpace software
    Contacto | Sugerencias
    Metadatos sujetos a:licencia de Creative Commons Reconocimiento 4.0 España
     

     

    Listar

    Todo UCreaComunidades y coleccionesFecha de publicaciónAutoresTítulosTemasEsta colecciónFecha de publicaciónAutoresTítulosTemas

    Mi cuenta

    AccederRegistrar

    Estadísticas

    Ver Estadísticas
    Sobre UCrea
    Qué es UcreaGuía de autoarchivoArchivar tesisAcceso abiertoGuía de derechos de autorPolítica institucional
    Piensa en abierto
    Piensa en abierto
    Compartir

    UNIVERSIDAD DE CANTABRIA

    Repositorio realizado por la Biblioteca Universitaria utilizando DSpace software
    Contacto | Sugerencias
    Metadatos sujetos a:licencia de Creative Commons Reconocimiento 4.0 España