dc.description.abstractThis work is focused on the design, fabrication, and performance analysis of a square-law Schottky diodedetector based on lossy transmission lines working under cryogenic temperature (15 K). The design analysis of a microwave detector, based on a planar gallium-arsenide low effective Schottky barrier height diode, is reported, which is aimed for achieving large input return loss as well as flat sensitivity versus frequency. The designed circuit demonstrates good sensitivity, as well as a good return loss in a wide bandwidth at Ka-band, at both room (300 K) and cryogenic (15 K) temperatures. A good sensitivity of 1000 mV/mW and input return loss better than 12 dB have been achieved when it works as a zero-bias Schottky diodedetector at room temperature, increasing the sensitivity up to a minimum of 2200 mV/mW, with the need of a DC bias current, at cryogenic temperature.es_ES
dc.description.sponsorshipThis work has been funded by the Spanish Ministry for Economy and Competitiveness under the CONSOLIDER-INGENIO 2010 programme under the Reference No. CSD2010-00064. The authors would like to thank Eva Cuerno and Ana Pérez for the assistance in the assembly of the circuit.es_ES
dc.format.extent8 p.es_ES
dc.language.isoenges_ES
dc.publisherAmerican Institute of Physicses_ES
dc.rights© 2016 American Institute of Physics. This article may be downloaded for personal use only. Any other use requires prior permission of the author and the American Institute of Physics. The following article appeared in Review of Scientific Instruments, 2016, 87(1), 014706 and may be found at https://doi.org/10.1063/1.4939730.es_ES
dc.sourceReview of Scientific Instruments, 2016, 87(1), 014706es_ES
dc.titlePerformance evaluation of a lossy transmission lines based diode detector at cryogenic temperaturees_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.relation.publisherVersionhttps://doi.org/10.1063/1.4939730es_ES
dc.rights.accessRightsopenAccesses_ES
dc.identifier.DOI10.1063/1.4939730
dc.type.versionpublishedVersiones_ES


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo