dc.contributor.author | Mirapeix Serrano, Jesús María | |
dc.contributor.author | Ruiz Lombera, Rubén | |
dc.contributor.author | Valdiande Gutiérrez, José Julián | |
dc.contributor.author | Cobo García, Adolfo | |
dc.contributor.author | López Higuera, José Miguel | |
dc.contributor.other | Universidad de Cantabria | es_ES |
dc.date.accessioned | 2017-01-24T15:34:21Z | |
dc.date.available | 2017-01-24T15:34:21Z | |
dc.date.issued | 2016-05 | |
dc.identifier.issn | 1530-437X | |
dc.identifier.issn | 1558-1748 | |
dc.identifier.other | TEC2013-47264-C2-1-R | es_ES |
dc.identifier.uri | http://hdl.handle.net/10902/10128 | |
dc.description.abstract | In this paper an analysis on the suitability of employing a colorimetric analysis of the acquired plasma spectra to perform on-line arc-welding quality monitoring will be discussed. Different colorimetric parameters like the color temperature or the parameters associated with the hue, saturation, luminance color space will be evaluated in comparison with the standard approach based on the estimation of the plasma electronic temperature. This approach does not require the identification of the emission lines involved in the analysis, thus giving rise to a more efficient solution in terms of computational efficiency, and avoiding unambiguous identifications that may give rise to incorrect results. In particular, experimental tests performed with a tungsten inert gas arc-welding process will show the feasibility of using the proposed solution and its ability to perform an online detection of different welding perturbations. | es_ES |
dc.description.sponsorship | This work has been supported by the project TEC2013-47264-C2-1-R. | es_ES |
dc.format.extent | 6 p. | es_ES |
dc.language.iso | eng | es_ES |
dc.publisher | Institute of Electrical and Electronics Engineers Inc. | es_ES |
dc.rights | © 2016 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. | es_ES |
dc.source | IEEE Sensors Journal, 2016, 16(10), 3465-3471 | es_ES |
dc.subject.other | Optical fiber sensor | es_ES |
dc.subject.other | On-line monitoring | es_ES |
dc.subject.other | Plasma spectroscopy | es_ES |
dc.subject.other | Arc-welding | es_ES |
dc.subject.other | Quality assurance | es_ES |
dc.subject.other | Colorimetry | es_ES |
dc.title | Colorimetric analysis for on-line arc-welding diagnostics by means of plasma optical spectroscopy | es_ES |
dc.type | info:eu-repo/semantics/article | es_ES |
dc.relation.publisherVersion | https://doi.org/10.1109/JSEN.2015.2413057 | es_ES |
dc.rights.accessRights | openAccess | es_ES |
dc.identifier.DOI | 10.1109/JSEN.2015.2413057 | |
dc.type.version | acceptedVersion | es_ES |