    Colorimetric analysis for on-line arc-welding diagnostics by means of plasma optical spectroscopy

    Ver/Abrir
    ColorimetricAnalysis ... (387.7Kb)
    Identificadores
    URI: http://hdl.handle.net/10902/10128
    DOI: 10.1109/JSEN.2015.2413057
    ISSN: 1530-437X
    ISSN: 1558-1748
    Compartir
    RefworksMendeleyBibtexBase
    Estadísticas
    Ver Estadísticas
    Google Scholar
    Registro completo
    Mostrar el registro completo DC
    Autoría
    Mirapeix Serrano, Jesús MaríaAutoridad Unican; Ruiz Lombera, RubénAutoridad Unican; Valdiande Gutiérrez, José JuliánAutoridad Unican; Cobo García, AdolfoAutoridad Unican; López Higuera, José MiguelAutoridad Unican
    Fecha
    2016-05
    Derechos
    © 2016 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.
    Publicado en
    IEEE Sensors Journal, 2016, 16(10), 3465-3471
    Editorial
    Institute of Electrical and Electronics Engineers Inc.
    Enlace a la publicación
    https://doi.org/10.1109/JSEN.2015.2413057
    Palabras clave
    Optical fiber sensor
    On-line monitoring
    Plasma spectroscopy
    Arc-welding
    Quality assurance
    Colorimetry
    Resumen/Abstract
    In this paper an analysis on the suitability of employing a colorimetric analysis of the acquired plasma spectra to perform on-line arc-welding quality monitoring will be discussed. Different colorimetric parameters like the color temperature or the parameters associated with the hue, saturation, luminance color space will be evaluated in comparison with the standard approach based on the estimation of the plasma electronic temperature. This approach does not require the identification of the emission lines involved in the analysis, thus giving rise to a more efficient solution in terms of computational efficiency, and avoiding unambiguous identifications that may give rise to incorrect results. In particular, experimental tests performed with a tungsten inert gas arc-welding process will show the feasibility of using the proposed solution and its ability to perform an online detection of different welding perturbations.
    Colecciones a las que pertenece
    • D50 Artículos [312]
    • D50 Proyectos de Investigación [404]

    UNIVERSIDAD DE CANTABRIA

    Repositorio realizado por la Biblioteca Universitaria utilizando DSpace software
    Contacto | Sugerencias
    Metadatos sujetos a:licencia de Creative Commons Reconocimiento 4.0 España
     

     

    Listar

    Todo UCreaComunidades y coleccionesFecha de publicaciónAutoresTítulosTemasEsta colecciónFecha de publicaciónAutoresTítulosTemas

    Mi cuenta

    AccederRegistrar

    Estadísticas

    Ver Estadísticas
    Sobre UCrea
    Qué es UcreaGuía de autoarchivoArchivar tesisAcceso abiertoGuía de derechos de autorPolítica institucional
    Piensa en abierto
    Piensa en abierto
    Compartir

    UNIVERSIDAD DE CANTABRIA

    Repositorio realizado por la Biblioteca Universitaria utilizando DSpace software
    Contacto | Sugerencias
    Metadatos sujetos a:licencia de Creative Commons Reconocimiento 4.0 España