    Iterative Otsu's method for OCT improved delineation in the aorta wall

    Ver/Abrir
    Iterative Otsu’s ... (782.6Kb)
    Identificadores
    URI: http://hdl.handle.net/10902/10059
    DOI: 10.1117/12.2183720
    ISBN: 978-1-62841-706-7
    ISSN: 0277-786X
    ISSN: 1996-756X
    Compartir
    RefworksMendeleyBibtexBase
    Estadísticas
    Ver Estadísticas
    Google Scholar
    Registro completo
    Mostrar el registro completo DC
    Autoría
    Alonso Saro, Daniel; Real Peña, EusebioAutoridad Unican; Val Bernal, José FernandoAutoridad Unican; Revuelta Soba, José ManuelAutoridad Unican; Pontón Cortina, AlejandroAutoridad Unican; Calvo Díez, Marta; Mayorga Fernández, Marta María; López Higuera, José MiguelAutoridad Unican; Conde Portilla, Olga MaríaAutoridad Unican
    Fecha
    2015
    Derechos
    © 2015 Society of Photo-Optical Instrumentation Engineers and Optical Society of America. One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited.
    Publicado en
    Daniel Alonso, Eusebio Real, Jose F. Val-Bernal, José M. Revuelta, Alejandro Pontón, Marta Calvo Diez, Marta Mayorga, José M. López-Higuera, Olga M. Conde " Iterative Otsu's method for OCT improved delineation in the aorta wall ", in European Conference on Biomedical Optics: Optical Coherence Imaging Techniques and Imaging in Scattering Media, Brett E. Bouma, Maciej Wojtkowski, eds., Vol. 9541 of Proceedings of SPIE-OSA Biomedical Optics, 95411A (2015)
    Editorial
    SPIE Society of Photo-Optical Instrumentation Engineers -
    The Optical Society (OSA)
    Enlace a la publicación
    http://dx.doi.org/10.1117/12.2183720
    Palabras clave
    OCT
    Aortic wall degradation
    Ascending thoracic aorta
    Otsu’s method
    Resumen/Abstract
    Degradation of human ascending thoracic aorta has been visualized with Optical Coherence Tomography (OCT). OCT images of the vessel wall exhibit structural degradation in the media layer of the artery, being this disorder the final trigger of the pathology. The degeneration in the vessel wall appears as low-reflectivity areas due to different optical properties of acidic polysaccharides and mucopolysaccharides in contrast with typical ordered structure of smooth muscle cells, elastin and collagen fibers. An OCT dimension indicator of wall degradation can be generated upon the spatial quantification of the extension of degraded areas in a similar way as conventional histopathology. This proposed OCT marker can offer in the future a real-time clinical perception of the vessel status to help cardiovascular surgeons in vessel repair interventions. However, the delineation of degraded areas on the B-scan image from OCT is sometimes difficult due to presence of speckle noise, variable signal to noise ratio (SNR) conditions on the measurement process, etc. Degraded areas can be delimited by basic thresholding techniques taking advantage of disorders evidences in B-scan images, but this delineation is not optimum in the aorta samples and requires complex additional processing stages. This work proposes an optimized delineation of degraded areas within the aorta wall, robust to noisy environments, based on the iterative application of Otsu’s thresholding method. Results improve the delineation of wall anomalies compared with the simple application of the algorithm. Achievements could be also transferred to other clinical scenarios: carotid arteries, aorto-iliac or ilio-femoral sections, intracranial, etc.
    Colecciones a las que pertenece
    • D06 Congresos [25]
    • D06 Proyectos de investigación [47]
    • D50 Congresos [464]
    • D50 Proyectos de Investigación [404]
    • IDIVAL Proyectos de investigación [191]

    UNIVERSIDAD DE CANTABRIA

    Repositorio realizado por la Biblioteca Universitaria utilizando DSpace software
    Contacto | Sugerencias
    Metadatos sujetos a:licencia de Creative Commons Reconocimiento 4.0 España
     

     

    Listar

    Todo UCreaComunidades y coleccionesFecha de publicaciónAutoresTítulosTemasEsta colecciónFecha de publicaciónAutoresTítulosTemas

    Mi cuenta

    AccederRegistrar

    Estadísticas

    Ver Estadísticas
    Sobre UCrea
    Qué es UcreaGuía de autoarchivoArchivar tesisAcceso abiertoGuía de derechos de autorPolítica institucional
    Piensa en abierto
    Piensa en abierto
    Compartir

    UNIVERSIDAD DE CANTABRIA

    Repositorio realizado por la Biblioteca Universitaria utilizando DSpace software
    Contacto | Sugerencias
    Metadatos sujetos a:licencia de Creative Commons Reconocimiento 4.0 España