@conference{10902/18168, year = {2019}, url = {http://hdl.handle.net/10902/18168}, abstract = {Two-sample phase locked loop (2S PLL) with harmonic filtering capacity is used in a non-linear control (NLC) for a current sensorless Boost power factor corrector (PFC). The objective is to provide the sensorless NLC with a PLL based zero-crossing detector (ZCD) reference to obtain a sinusoidal line current, even under harmonically distorted grid voltages, which requires a proper grid synchronization, especially in the case of weak electrical grids. The resulting line current using the proposed 2S PLL and a ZCD are compared in simulation and experimentally.}, organization = {This work has been supported by the Spanish Ministry of Science and Innovation under Projects TEC2014-52316-R ECOTREND - Estimation and Optimal Control for Energy Conversion with Digital Devices and RTI2018-095138-BC31 PEGIA - Power Electronics for the Grid and Industry Applications}, publisher = {Institute of Electrical and Electronics Engineers, Inc.}, publisher = {IEEE 20th Workshop on Control and Modeling for Power Electronics (COMPEL), Toronto, Ontario, 2019, 47-51}, title = {Low THDi controller for current sensorless single phase rectifiers using a two-sample phase locked loop}, author = {Lamo Anuarbe, Paula and Ruiz Robredo, Gustavo A. and Pigazo López, Alberto and Azcondo Sánchez, Francisco Javier}, }