@misc{10902/14911, year = {2018}, month = {10}, url = {http://hdl.handle.net/10902/14911}, abstract = {RESUMEN: En este proyecto se desarrollará un sistema de medida que permita conocer parámetros tales como la ganancia y la temperatura equivalente de ruido o figura de ruido en amplificadores de microondas a temperatura ambiente y en criogenia, en la banda W (75-110 GHz). En primer lugar, se caracterizará la figura de ruido y la ganancia de un amplificador de bajo ruido en la banda Q (33-50 GHz) tanto a temperatura ambiente, como posteriormente a temperatura criogénica mediante dos técnicas de medida distintas; el método del atenuador frío, y el método carga calentada. Finalmente se analizarán las diferencias entre ambas técnicas comparando los resultados obtenidos. Posteriormente, se diseñará el sistema de medida en banda W, comenzando por la caracterización de un conversor de frecuencia y seguidamente, se desarrollará el sistema de medida de ruido a temperatura ambiente. Una vez realizada la medida de ganancia y figura de ruido a temperatura ambiente se procederá a desarrollar el sistema de medida en temperatura criogénica. Para ello se comienza diseñando una nueva ventana de vacío en guía WR10 para el criostato, la cual será la salida del sistema. Para el diseño de esta ventana habrá que medir previamente los parámetros de Scattering de los componentes necesarios que conforman la ventana. Tras acoplar la ventana al criostato, se realizarán dos medidas de la temperatura de ruido de un amplificador comercial comparando los resultados con los obtenidos en el Centro Astronómico de Yebes (CAY).}, abstract = {ABSTRACT: In this project, a measurement system will be developed. This system will allow to know parameters such as the gain and the equivalent noise temperature or the noise figure in microwave amplifiers at room temperature and in cryogenics, in the W band (75-110 GHz). In the first place, the noise figure and the gain of a low noise amplifier in the Q band (33-50 GHz) at room temperature are characterized, and then in cryogenics by means of two different techniques; cold attenuator method and heated charge method. Finally, the differences between both techniques will be analyzed and the results will be compared. Subsequently, the measurement system will be designed in W band, starting with the characterization of a frequency converter and then, the noise measurement system will be developed at room temperature. Once the measure of gain and figure of noise at room temperature has been carried out, the cryogenic temperature measurement system will be developed, for which a new vacuum window in WR10 guide for the cryostat will be designed, which will be the output of the system. For the design of this window it will be necessary to previously measure the Scattering parameters of the components that make up the window. After coupling the window to the cryostat, two measurements of the noise temperature of a commercial amplifier will be made comparing the results with those obtained in the ‘Centro Astronómico de Yebes’ (CAY).}, title = {Desarrollo de un sistema de medida de temperatura de ruido en criogenia en la banda W (75-110 GHz)}, author = {Martos Mateos, Sara}, }